Sonographic fetal weight estimation prior to delivery: analysis of accuracy and interobserver variability between obstetrician and radiologist

نویسندگان

  • Hüseyin Aksoy
  • Özkan Özdamar
  • Ülkü Aksoy
  • Fulya Çağlı
  • Özge Idem Karadağ
  • Gökhan Açmaz
  • Mustafa Alparslan Babayiğit
  • Turgut Aydın
چکیده

The aim of this study was to evaluate the interobserver reliability of sonographic fetal weight estimation between experienced obstetrician and radiologist immadiately prior to delivery and to compare the sonographic accuracies of estimated fetal weights (EFW) between the sonographers. This was a prospective study of singleton pregnancies that underwent sonographic fetal weight estimation prior to scheduled delivery. One obstetrician and one radiologist, performed all examinations prior to delivery. Sonographic fetal weight estimations were obtained from each ultrasonographic examination. EFWs were compared with the actual birth weight (ABW) and interobserver reliability of sonographic fetal weight estimation between two sonographers was assessed. A total of 245 subjects were included. Inter-observer reliability coefficient for EFW was 0.864 (95% confidence interval: 0.825-0.894, P < 0.001). Mean values of EFWs by radiologist and obstetrician did not significantly differ (P = 0.480) while both did significantly differ from the ABW (P < 0.001, for both comparisons). The mean absolute error for EFW obtained by radiologist and obsterician was 227 (± 160) and 197 (± 138), respectively (P < 0.01). The mean absolute percentage error for EFW obtained by radiologist and obsterician was 7.09 (± 5.17) and 6.15 (± 4.38), respectively (P < 0.01). EFWs measured by radiologists and obstetricians are similar but both are significantly distant from the ABW. However, obstetricians measure EFW significantly more accurate than the radiologists do.

منابع مشابه

Sonographic estimation of fetal weight in term pregnant women

Introduction: Deviation from normal fetal weight and growth contribute to morbidity and mortality in the perinatal period. Over 50 formulas for EFW (estimated fetal weight) have been published and yet the ideal formula has not been determined. The objective of this study was to evaluate the accuracy of sonographic estimation of fetal weight using Hadlock formula in comparison to birth weight....

متن کامل

Analysis of factors influencing the ultrasonic fetal weight estimation.

OBJECTIVE The aim of our study was the evaluation of sonographic fetal weight estimation taking into consideration 9 of the most important factors of influence on the precision of the estimation. METHODS We analyzed 820 singleton pregnancies from 22 to 42 weeks of gestational age. We evaluated 9 different factors that potentially influence the precision of sonographic weight estimation (time ...

متن کامل

Estimation of fetal weight by measurement of fetal thigh soft-tissue thickness in the late third trimester.

OBJECTIVE The accuracy of current formulae for the sonographic estimation of fetal weight (EFW) is compromised by significant intra- and interobserver variability of biometrical measurements, particularly circumferences. The aim of this study was to assess the reliability of the linear measurement of mid-thigh soft-tissue thickness (STT) and to derive a novel formula for EFW. METHODS This was...

متن کامل

Accuracy of sonographic fetal weight estimation within 14 days of delivery in a Jordanian population using Hadlock formula 1.

OBJECTIVES To assess the accuracy of sonographic fetal weight estimation within 14 days of delivery in a Jordanian population using Hadlock formula 1 in the third trimester. MATERIALS AND METHODS Estimated fetal weights and actual fetal weights data were collected from the medical records of pregnant women who had undergone sonographic fetal weight estimation within 14 days of delivery over t...

متن کامل

Inm-1: Indication of First Trimester Sonongraphy

Improvement in ultrasound technology, including transvaginalsonography and higher frequency probes, has led to a better understanding of early pregnancy development. The first trimester ultrasound have been identified that can be used to reassure women that their pregnancy is progressing normally or abnormal them that their pregnancy will fail. The practicing radiologist and obstetrician must b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016