Dynamic interface pressure distributions of two transtibial prosthetic socket concepts.

نویسندگان

  • Tim Dumbleton
  • Arjan W P Buis
  • Angus McFadyen
  • Brendan F McHugh
  • Geoff McKay
  • Kevin D Murray
  • Sandra Sexton
چکیده

In this study, we investigated and compared the dynamic interface pressure distribution of hands-off and hands-on transtibial prosthetic systems by means of pressure mapping. Of the 48 established unilateral amputees recruited, half (n = 24) had been wearing pressure-cast prostheses (IceCast Compact) and the other half (n = 24) had been wearing hand-cast sockets of the patellar tendon bearing design. We measured the dynamic pressure profile of more than 90% of the area within each prosthetic socket by means of four Tekscan F-Scan socket transducer arrays. We compared the interface pressure between socket concepts. We found that the distribution of dynamic pressure at the limb-socket interface was similar for the two intervention (socket prescription) groups. However, a significant difference was found in the magnitude of the interface pressure between the two socket concepts; the interface pressures recorded in the hands-off sockets were higher than those seen in the hands-on concept. Despite the differences in interface pressure, the level of satisfaction with the sockets was similar between subject groups. The sockets instrumented for this study had been in daily use for at least 6 months, with no residual-limb health problems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research

The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During t...

متن کامل

Interface pressure in transtibial socket during ascent and descent on stairs and its effect on patient satisfaction.

BACKGROUND Transtibial amputees encounter stairs and steps during their daily activities. The excessive pressure between residual limb/socket may reduce the walking capability of transtibial prosthetic users during ascent and descent on stairs. The purposes of the research were to evaluate the interface pressure between Dermo (shuttle lock) and Seal-In X5 (prosthetic valve) interface systems du...

متن کامل

Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis

Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressu...

متن کامل

Videofluoroscopic evaluation of prosthetic fit and residual limbs following transtibial amputation.

The clinical examination of residual limb complications is usually subjective and may lead to inappropriate, expensive adjustments or replacement of the prosthesis. Plain films and xeroradiography only provide static images of the residual limb and socket. The purpose of this pilot study was to develop a videofluoroscopic technique to evaluate dynamic residual limb-socket relationships during g...

متن کامل

A Variable-Impedance Prosthetic Socket for a Transtibial Amputee Designed from Magnetic Resonance Imaging Data

This article evaluates the design of a variable impedance prosthetic (VIPr) socket for a transtibial amputee using computeraided design andmanufacturing (CAD/CAM) processes. Compliant features are seamlessly integrated into a three-dimensional printed socket to achieve lower interface peak pressures over bony protuberances by using biomechanical data acquired through surface scanning and magnet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 2009