Fixation of the proximal interphalangeal arthrodesis with the use of an intraosseous loop of stainless-steel wire suture.
نویسندگان
چکیده
A wide range of options is available to surgeons for fixation of the proximal interphalangeal joint when arthrodesis is undertaken for repair of the hammertoe deformity. In this technical report, we describe the use of an intraosseous loop of stainless-steel wire for permanent stabilization of the interface between the proximal and middle phalanges during fusion of the interphalangeal joint.
منابع مشابه
Fixation of extra articular fracture of inferior pole of patella by on needle stainless steel suture wire
The patella is the largest sesamoid bone in the body. As the patella bone is responsible for the strong extensor mechanism of the knee joint, its reconstruction and anatomical restoration after fracture is always desirable over excision. Extra articular fracture of lower pole of patella accounts for less than 10 percent of all patellar fractures. The treatment of these fractures is complicated,...
متن کاملBiomechanical evaluation of 5 fixation devices for proximal interphalangeal joint arthrodesis.
PURPOSE To determine in a cadaver model which, among 5 fixation methods for proximal interphalangeal (PIP) joint arthrodesis, has the greatest stiffness. METHODS Thirty-five cadaver digits were randomly assigned to 1 of 5 fixation groups: oblique K-wire with coronal intraosseous wiring, tension-band wire (TBW), dorsal plate, intramedullary linked screw (IMS), and 90/90 wiring (90/90W). Testin...
متن کاملProphylactic Cerclage With Braided Polyblend Suture During Femoral Broaching.
Femur fractures occur during broaching and impaction of the implant during hip arthroplasty. Prophylactic cerclage of the proximal femur with braided cable and steel wire has been shown to decrease hoop stresses and has been posited as a way to decrease the incidence of intraoperative fracture. In this biomechanical study, the authors investigated the strain across the proximal femur during bro...
متن کاملThe use of three types of suture and stainless steel wire tension banding for the fixation of simulated olecranon fractures: a comparison study in cadaver elbows.
Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied u...
متن کاملBraided Polyester Suture Fatigue Failure When Treating Transverse Patellar Fracture: A Case Report
The incidence of patellar fractures accounts for almost 1% of all skeletal fractures. In case of a displaced patellar fracture, surgical intervention is often advocated for earlier stability, restoration of knee motion, and shortened morbidity. Among various fixations, the AO modified tension band technique, which incorporates two parallel Kirschner wires with an anterior tension band, is the m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons
دوره 48 3 شماره
صفحات -
تاریخ انتشار 2009