WE-G-217A-01: Fast Recovery Driven Equilibrium with Automated Switching to Avoid Artifacts.
نویسندگان
چکیده
PURPOSE To reduce image artifacts from the unnecessary use of driven- equilibrium. Driven-equilibrium methods known as fast recovery, RESTORE, or DRIVE enable reduction of repetition time (TR) and hence acquisition time in RARE (FSE or TSE) imaging by applying additional RF pulses following each echotrain to accelerate T1 recovery. Fast recovery (FR) techniques are most useful when TR is less than 4*T1. For neuroimaging, the benefit of FR diminishes as TR increases beyond ∼3s. In regions of rapid susceptibility change such as near metallic implants, FR techniques can introduce artifact because the magnetization is not properly rephased when the FR pulses are applied. In our clinical practice we observe that technologists frequently adjust TR over a range of 2-5s on a patient- specific basis to minimize scan time. We do not observe, however, that technologists reliably disable FR when TR is long enough, introducing possible artifacts. METHODS An FR-FSE pulse sequence was modified to automatically disable the FR feature whenever TR exceeded a user-defined threshold (TR0). Under IRB approval, a healthy volunteer was scanned with the sequence using TRs ranging from 1-5s, and TR0=900ms or 6s. Contrast- to-noise measurements were made between CSF, gray matter and white matter for each dataset. RESULTS The volunteer study shows decreasing benefit of FR as TRs increase beyond 3s. A patient with bilateral auditory brainstem implants scanned with and without FR demonstrates FR-induced artifacts. CONCLUSIONS We demonstrate an FR-FSE pulse sequence that automatically disables fast-recovery whenever TR exceeds an operator- selected threshold. The pulse sequence avoids unnecessary artifacts in regions of rapid susceptibility changes, while retaining the advantages of FR when TR<TR0. Clinical images from a patient with bilateral auditory brainstem implants demonstrate potential artifacts introduced by FR, and the benefits of automatically avoiding unnecessary use of FR.
منابع مشابه
Dual Space Control of a Deployable Cable Driven Robot: Wave Based Approach
Known for their lower costs and numerous applications, cable robots are an attractive research field in robotic community. However, considering the fact that they require an accurate installation procedure and calibration routine, they have not yet found their true place in real-world applications. This paper aims to propose a new controller strategy that requires no meticulous calibration and ...
متن کاملPerformance Investigation of Multi-Phase VSI with Simple PWM Switching Techniques
This paper presents the performance investigation of multi-phase voltage source inverter (VSI) with simple PWM switching techniques namely the harmonic injection and offset injection method. The technique discussed in this paper is easy to implement and avoid complicated controlling algorithm adapted in SVPWM technique. A generalized algorithm suitable for odd number of phases is developed in M...
متن کاملAutomated Analyses of Model-Driven Artifacts
Over the past years, there has been an increase in the application of model driven engineering in industry. Similar to traditional software engineering, understanding how technologies are actually used in practice is essential for developing good tooling, and decision making processes. Unfortunately, obtaining and analyzing empirical data in a model-driven context is still tedious and time cons...
متن کاملشرایط گذار به اشتعال غیرتعادلی در افروزش حجمی هدفهای کروی ساده
In this Research, the transition from equilibrium ignition to non-equilibrium burn was studied by DEIRA4 code for simple spherical targets with the dimensions of several mm. It consisted of inner DT fuel and outer Au layers driven by the 209Bi heavy ions beam. Because of their higher plasma opacity, it was expected that they could trap much of the produced charged particles, radiation or even f...
متن کاملCervical spine: three-dimensional fast spin-echo MR imaging--improved recovery of longitudinal magnetization with driven equilibrium pulse.
Author contributions: Guarantor of integrity of entire study, E.R.M.; study concepts and design, E.R.M.; definition of intellectual content, E.R.M.; literature research, E.R.M.; clinical studies, E.R.M.; data acquisition, E.R.M., R.I.; data analysis, E.R.M., R.I.; manuscript preparation, E.R.M., R.I.; manuscript editing, E.R.M., R.I., P.J.M.F.; manuscript review, E.R.M., R.I., P.J.M.F. Cervical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part28 شماره
صفحات -
تاریخ انتشار 2012