Clean Colon Software Program (CCSP), Proposal of a standardized Method to quantify Colon Cleansing During Colonoscopy: Preliminary Results

نویسندگان

  • Erik Rosa-Rizzotto
  • Adrian Dupuis
  • Ennio Guido
  • Diego Caroli
  • Fabio Monica
  • Daniele Canova
  • Erica Cervellin
  • Renato Marin
  • Cristina Trovato
  • Cristiano Crosta
  • Silvia Cocchio
  • Vincenzo Baldo
  • Franca De Lazzari
چکیده

BACKGROUND AND STUDY AIMS Neoplastic lesions can be missed during colonoscopy, especially when cleansing is inadequate. Bowel preparation scales have significant limitations and no objective and standardized method currently exists to establish colon cleanliness during colonoscopy. The aims of our study are to create a software algorithm that is able to analyze bowel cleansing during colonoscopies and to compare it to a validate bowel preparation scale. PATIENTS AND METHODS A software application (the Clean Colon Software Program, CCSP) was developed. Fifty colonoscopies were carried out and video-recorded. Each video was divided into 3 segments: cecum-hepatic flexure (1st Segment), hepatic flexure-descending colon (2nd Segment) and rectosigmoid segment (3rd Segment). Each segment was recorded twice, both before and after careful cleansing of the intestinal wall. A score from 0 (dirty) to 3 (clean) was then assigned by CCSP. All the videos were also viewed by four endoscopists and colon cleansing was established using the Boston Bowel Preparation Scale. Interclass correlation coefficient was then calculated between the endoscopists and the software. RESULTS The cleansing score of the prelavage colonoscopies was 1.56 ± 0.52 and the postlavage one was 2,08 ± 0,59 (P < 0.001) showing an approximate 33.3 % improvement in cleansing after lavage. Right colon segment prelavage (0.99 ± 0.69) was dirtier than left colon segment prelavage (2.07 ± 0.71). The overall interobserver agreement between the average cleansing score for the 4 endoscopists and the software pre-cleansing was 0.87 (95 % CI, 0.84 - 0.90) and post-cleansing was 0.86 (95 % CI, 0.83 - 0.89). CONCLUSIONS The software is able to discriminate clean from non-clean colon tracts with high significance and is comparable to endoscopist evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two different methods of colon cleansing for afternoon-colonoscopy

Background: The appropriate colon cleansing is a major determinant of quality of colonoscopy. The aim of this study was to compare the efficacy and tolerability of the morning (AM) PEG (polyethylene glycol) solution to previous-evening (PM) PEG solution for the afternoon colonoscopy. Methods: This comparative study compared the AM to PM prep for afternoon outpatient colonoscopy. The subjects r...

متن کامل

Comparison of the Efficacy and Safety of Polyethylene Glycol and Senna Solutions in Colon Preparation before Colonoscopy in Dogs

Objective- The aim of this study was to evaluate the efficacy and safety of senna as an alternative or adjunct to polyethylene glycol (PEG) solution in dogs using colonoscopy and radiography.Design - Experimental study.Animals - 20 adult mongrel healthy dogs.Procedures- Dogs were randomly allocated to receive 1 of 4 different bowel preparation regimens including PEG, senna or ...

متن کامل

Computed Cleansing for Virtual Colonoscopy Using a Three-Material Transition Model

Virtual colonoscopy is a non-invasive technique for the detection of polyps. Currently, a clean colon is required; as without cleansing the colonic wall cannot be segmented. Enhanced bowel preparation schemes opacify intraluminal remains to enable colon segmentation. Computed cleansing (as opposed to physical cleansing of the bowels) allows removal of tagged intraluminal remains. This paper des...

متن کامل

Electronic Colon Cleansing by Colonic Material Tagging and Image Segmentation for Polyp Detection: Detection Model and Method Evaluation

Virtual colonoscopy provides a safe, non-invasive approach to screening colonic polyps using medical imaging and computer graphics technologies, where computer aided or automated detection plays an important role. For model-based detection using geometrical features, the entire colonic lumen must be delineated first. A critical step to obtain a cleansed colonic lumen relies on bowel preparation...

متن کامل

Pyogenic Liver Abscess as a Fatal Complication of Colonoscopy: a case report

Background: Colonoscopy is a safe and routinely-performed diagnostic and screening procedure for different colorectal diseases. The diagnostic and screening colonoscopy for is different for colon diseases. In order for colonoscopy, colon cleansing is required to prepare a detailed view into the intestinal lumen. Aim: This is a case report study of a patient with multiple pyogenic liver abscesse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015