A single camera roentgen stereophotogrammetry method for static displacement analysis.

نویسندگان

  • S W Gussekloo
  • B A Janssen
  • M George Vosselman
  • R G Bout
چکیده

A new method to quantify motion or deformation of bony structures has been developed, since quantification is often difficult due to overlaying tissue, and the currently used roentgen stereophotogrammetry method requires significant investment. In our method, a single stationary roentgen source is used, as opposed to the usual two, which, in combination with a fixed radiogram cassette holder, forms a camera with constant interior orientation. By rotating the experimental object, it is possible to achieve a sufficient angle between the various viewing directions, enabling photogrammetric calculations. The photogrammetric procedure was performed on digitised radiograms and involved template matching to increase accuracy. Co-ordinates of spherical markers in the head of a bird (Rhea americana), were calculated with an accuracy of 0.12mm. When these co-ordinates were used in a deformation analysis, relocations of about 0.5mm could be accurately determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new method for drawing the capacity spectrum for seismic analysis and structural rehabilitation

A review of previous studies shows that there are two general views on how to determine demand in structures through incremental nonlinear static analysis. In the first view, multi-modal methods are used to determine demand in structures. In this view, the applied load pattern is applied to the structure according to the shape of each vibration mode, assuming that the structure deformation foll...

متن کامل

Uncalibrated X-Ray Stereo Reconstruction

We describe a novel application of uncalibrated stereo reconstruction to Roentgen Stereophotogrammetry Analysis (RSA). In RSA, stereo X-ray images are taken of a bone containing a prosthesis (e.g. a replacement knee) and a number of metal markers. The aim is to recover the relative position of the prosthesis and markers in 3D. Accuracy in previous RSA methods has been limited by two factors: ma...

متن کامل

Damage Detection in Beam-like Structures using Finite Volume Method

In this paper the damage location in beam like-structure is determined using static and dynamic data obtained using finite volume method. The change of static and dynamic displacement due to damage is used to establish an indicator for determining the damage location. In order to assess the robustness of the proposed method for structural damage detection, three test examples including a static...

متن کامل

The use of Roentgen stereophotogrammetry to study micromotion of orthopaedic implants

Roentgen stereophotogrammetry is the most accurate Roentgen technique for three-dimensional assessment of micromotion of orthopaedic implants. The reported accuracy of Roentgen Stereophotogrammetric Analysis (RSA) ranges between 0.05 and 0.5 mm for translations and between 0.15j and 1.15j for rotations. Because of the high accuracy of RSA, small patient groups are in general sufficient to study...

متن کامل

A Target Displacement for Static Pushover Analysis to Estimate Seismic Demand of Eccentrically Braced Frames

A main challenge for performance-based seismic engineering is to develop simple, practical and precise methods for analyzing designed buildings and assessing existing structures to satisfy considerable performance objectives. Pushover analysis is a simplified nonlinear analysis technique that can be implemented for estimating the dynamic demands imposed on a structure under earthquake excitatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2000