Influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output

نویسندگان

  • Chen Shu-Lan
  • Lan Fang-Chen
  • Du Zhen-Shuang
  • Xu Ya-Ping
  • Zhao Hui-Ming
  • Zeng Cui-Ping
  • Miao Yu
چکیده

OBJECTIVE This study aimed to investigate the influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output (PICCO, made in Germany), and thereby to provide significant references for clinical practice. METHODS A total of 108 critical patients in stroke intensive care unit were identified. All these participants received transesophageal cardiac color Doppler ultrasound, and within 15 min PICCO equipment was utilized to monitor the relevant parameters, by means of 0 °C calibrating standard solution, and the injection speeds were 2-4, 5-7, and 8-10 s. Besides, the monitoring indicators were as follows, cardiac index, global ejection fraction, global end diastolic volume index. The potential correlations were evaluated between PICCO and transesophageal cardiac color Doppler ultrasound. RESULTS All the data was available, and the monitored parameters of PICOO at 2-4, 5-7, and 8-10 s were positively correlated with the parameters obtained from transesophageal cardiac color Doppler ultrasound (P < 0.05). Specially, it is worth emphasizing that the best correlation between them could be provided when the injection rate was 2-4 s. CONCLUSION When the injection rate at 2-4 s, the parameters obtained by PICOO were much closer to that of transesophageal cardiac color Doppler ultrasound. Furthermore, the parameters of PICOO obtained at 2-4 s could better reflect cardiac function of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Comparison of left ventricular and pulmonary arterial injection sites in determination of cardiac output by indicator dilution technique.

Cardiac outputs calculated from left ventricular indicator dilution curves were compared to outputs calculated from pulmonary arterial curves in 58 patients with a variety of cardiac abnormalities. Cardiac outputs calculated from left ventricular and pulmonary arterial curves differed by only 0.037 ± 0.052 LI mm. Individual measurements of cardiac output using left ventricular curves had an est...

متن کامل

Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement.

OBJECTIVE Pulse contour analysis can be used to provide beat-to-beat cardiac output (CO) measurement. The current study sought to evaluate this technique by comparing its results with lithium dilution CO (LiCO) measurements. DESIGN Prospective, observational study. SETTING Surgical intensive care unit. PATIENTS Twenty-two patients after cardiac or major noncardiac surgery. MEASUREMENTS ...

متن کامل

Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation.

PURPOSE The PiCCO System is a relatively new device allowing intermittent cardiac output monitoring by aortic transpulmonary thermodilution technique (Aorta intermittent) and continuous cardiac output monitoring by pulse contour analysis (Aorta continuous). The objective of this study was to assess the level of agreement of Aorta intermittent and Aorta continuous with intermittent (PA intermitt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2018