Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation

نویسندگان

  • Vivekanand A. Chatpalliwar
  • Pawan K. Porwal
  • Neeraj Upmanyu
چکیده

A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride (DTZ) together with its six related substances (Diltiazem sulphoxide, Imp-A, Imp-B, Imp-D, Imp-E, and Imp-F) in a laboratory mixture as well as in a novel tablet formulation developed in-house. Efficient chromatographic separation was achieved on a Hypersil BDS C18 (150 mm×4.6 mm, 5.0 μm) with mobile phase containing 0.2% Triethylamine (TEA) in gradient combination with acetonitrile (ACN) at a flow rate of 1.0 mL/min and the eluent was monitored at 240 nm. In the developed method, the resolution of DTZ from any pair of impurities was found to be greater than 2.0. The test solution and related substances were found to be stable in the diluent for 24 h. The developed method resolved the drug from its known impurities, stated above, and also from additional impurities generated when the formulation was subjected to forced degradation; the mass balance was found close to 99.9%. Regression analyses indicate correlation coefficient value greater than 0.997 for DTZ and its six known impurities. The LOD for DTZ and the known impurities was at a level below 0.02%. The method has shown good, consistent recoveries for DTZ (99.8-101.2%) and also for its six known impurities (97.2-101.3%). The method was found to be accurate, precise, linear, specific, sensitive, rugged, robust, and stability-indicating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

Stability-indicating UFLC method for uncoupling and estimation of impurities in clopidogrel, aspirin and omeprazole in their tablet dosage form using PDA detection

In this paper a fast and novel stability-indicating ultra fast LC method for separation and estimation of impurities in clopidogrel and aspirin in their combined tablet dosage form and omeprazole was developed. The separation of USP related substances of clopidogrel (A, B and C), aspirin (D), omeprazole (A, B and C) and few other unknown impurities was detected by using ultra fast liquid chroma...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012