Use of cylindrical titanium mesh and locking plates in anterior cervical fusion. Technical note.

نویسندگان

  • K Das
  • W T Couldwell
  • G Sava
  • R F Taddonio
چکیده

After performing anterior cervical corpectomy or discectomy for cervical spondolytic myelopathy or radiculopathy, iliac crest bone graft and fibular auto- or allograft is often used to achieve arthrodesis in the cervical spine. The purpose of this study was to evaluate the use of a cylindrical titanium mesh and locking plate system as an alternative technique in achieving anterior cervical fusion and maintaining lordosis. Hospital records and radiographs of 38 patients who underwent anterior cervical discectomies (28 patients) or corpectomies (10 patients) from 1995 to 1997 were reviewed retrospectively. All patients had undergone arthrodesis in which autograft and a cylindrical titanium mesh and anterior locking plate fixation were used after discectomy or corpectomy. There were 20 men and 18 women (mean age 46.1 years; range 34-72 years). Presenting symptoms included radiculopathy (61%), myelopathy (37%), and neck pain (2%). Preoperative and postoperative radiographs were studied, and data were obtained on the following: overall lordosis or kyphosis of the cervical spine, segmental lordosis or kyphosis at each surgically treated level, and evidence of fusion. In all of the patients in whom lordosis was present preoperatively, lordosis was maintained during the follow-up period. The overall fusion rate was 100%. The average change in overall lordosis or kyphosis related to the fixation devices was 1.2 degrees (range 1-5 degrees) the average segmental change was 2.3 degrees (range 0-5 degrees); and the mean follow up was 16 months (range 12-36 months). Anterior cervical fusion with cylindrical titanium mesh and cervical locking plate system is an effective method of achieving arthrodesis and maintaining alignment in the cervical spine. The construct may provide additional load-sharing function, and it avoids the use of cadaveric bone or the need for harvesting tricortical iliac crest autograft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-stage Treatment of Osteomyelitis of the Cervical Spine Using Anterior Instrumentation and Titanium Mesh Cages.

STUDY DESIGN A case series. OBJECTIVE The aim of this study was to evaluate the clinical outcomes of patients with osteomyelitis of the cervical spine who were treated with single-stage anterior debridement and fusion using titanium mesh cages along with anterior plates. SUMMARY OF BACKGROUND DATA There have been few studies in single-stage surgical treatment of osteomyelitis of the cervica...

متن کامل

Anterior decompression and internal fixation for lower cervical spine dislocation

Objective: To summarize neurological outcome and complications after skull distraction combination of anterior cervical surgery managed with corpectomy, titanium mesh cage reconstruction, and cervical locking plate. Methods: A total of 42 patients with lower cervical spine fracture and dislocation were included in this study between May 2009 and September 2014. The average follow-up time was 18...

متن کامل

Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy.

BACKGROUND To determine the safety and effectiveness of the use of titanium mesh cages (TMCs) and anterior cervical plates (ACPs) for interbody fusion after anterior cervical corpectomy. METHODS From June 2001 to June 2003, 15 patients underwent reconstruction with TMCs and ACPs for interbody fusion after anterior cervical corpectomy in our hospital. The mean follow-up is 13.6 months (range, ...

متن کامل

New Dynamic Plate System Combined with Titanium Mesh Cage and Bone Graft in the Treatment of Cervical Spondylosis.

AIM Dynamic plates have been popularized to promote cervical spine fusion. There are no studies comparing the effectiveness and complications between traditional static plates and new dynamic plates (Vectra-T, Synthes, Switzerland). MATERIAL AND METHODS From June 2009 to October 2012, 70 patients underwent anterior cervical corpectomy and fusion (ACCF) in our hospital for the treatment of cer...

متن کامل

Biomechanical study of a novel self-locking plate system for anterior cervical fixation

BACKGROUND Anterior cervical plate had developed continuously, and this study aimed to assess the biomechanics of a novel self-locking plate system for anterior cervical fixation designed by ourselves. METHODS Twelve anterior cervical plates (i.e., six novel plates and six DePuy plates) were subjected to a pull-out test and a fatigue test. In addition, 12 C1-T1 cervical spine specimens underw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 94 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2001