Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature.
نویسندگان
چکیده
OBJECTIVES : A systematic review of the literature to determine the ability of dynamic changes in arterial waveform-derived variables to predict fluid responsiveness and compare these with static indices of fluid responsiveness. The assessment of a patient's intravascular volume is one of the most difficult tasks in critical care medicine. Conventional static hemodynamic variables have proven unreliable as predictors of volume responsiveness. Dynamic changes in systolic pressure, pulse pressure, and stroke volume in patients undergoing mechanical ventilation have emerged as useful techniques to assess volume responsiveness. DATA SOURCES : MEDLINE, EMBASE, Cochrane Register of Controlled Trials and citation review of relevant primary and review articles. STUDY SELECTION : Clinical studies that evaluated the association between stroke volume variation, pulse pressure variation, and/or stroke volume variation and the change in stroke volume/cardiac index after a fluid or positive end-expiratory pressure challenge. DATA EXTRACTION AND SYNTHESIS : Data were abstracted on study design, study size, study setting, patient population, and the correlation coefficient and/or receiver operating characteristic between the baseline systolic pressure variation, stroke volume variation, and/or pulse pressure variation and the change in stroke index/cardiac index after a fluid challenge. When reported, the receiver operating characteristic of the central venous pressure, global end-diastolic volume index, and left ventricular end-diastolic area index were also recorded. Meta-analytic techniques were used to summarize the data. Twenty-nine studies (which enrolled 685 patients) met our inclusion criteria. Overall, 56% of patients responded to a fluid challenge. The pooled correlation coefficients between the baseline pulse pressure variation, stroke volume variation, systolic pressure variation, and the change in stroke/cardiac index were 0.78, 0.72, and 0.72, respectively. The area under the receiver operating characteristic curves were 0.94, 0.84, and 0.86, respectively, compared with 0.55 for the central venous pressure, 0.56 for the global end-diastolic volume index, and 0.64 for the left ventricular end-diastolic area index. The mean threshold values were 12.5 +/- 1.6% for the pulse pressure variation and 11.6 +/- 1.9% for the stroke volume variation. The sensitivity, specificity, and diagnostic odds ratio were 0.89, 0.88, and 59.86 for the pulse pressure variation and 0.82, 0.86, and 27.34 for the stroke volume variation, respectively. CONCLUSIONS : Dynamic changes of arterial waveform-derived variables during mechanical ventilation are highly accurate in predicting volume responsiveness in critically ill patients with an accuracy greater than that of traditional static indices of volume responsiveness. This technique, however, is limited to patients who receive controlled ventilation and who are not breathing spontaneously.
منابع مشابه
How accurate is pulse pressure variation as a predictor of fluid responsiveness?
231– 41 2. De Hert SG: Assessment of Fluid Responsiveness Insights in a “gray zone.” ANESTHESIOLOGY 2011; 115:229 –30 3. Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature. Crit Care Med 2009; 37:2642–7 4. Pinsky MR: Hemodynamic evaluation and monitor...
متن کاملRespiratory Variation in Pulse Oximetry: A Simple Fluid Responsiveness Parameter
Respiratory variation in arterial pulse pressure (ΔPP) has been shown to be the most accurate predictor of fluid responsiveness in mechanically ventilated patients, with a predictive cutoff value of 13%. However, this dynamic parameter is invasive and not widely available. The pulse oximetry plethysmographic (POP) signal resembles the arterial pressure waveform in both shape and amplitude varia...
متن کاملThe effect of Therapeutic Touch on Physiological Variables of Mechanically Ventilated Patients in Intensive Care Units
Background: Underlying diseases and aggressive procedures, such as different types of surgery and care, for patients with critical conditions in intensive care units (ICU) may be associated with physiological disorders. Objectives: This study intended to determine the effect of therapeutic touch on physiological variables of patients undergoing mechanical ventilation in ICU. Methods: This...
متن کاملIs it safe to use supraglottic airway in children with difficult airways?
blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001; 119: 867–73 16 Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients. A systematic review of the literature. Crit Care Med 2009; 37: 2642–7 17 Benes J, Chytra I, Altmann P, et al. Intr...
متن کاملPleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.
BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 37 9 شماره
صفحات -
تاریخ انتشار 2009