Stationary Frame Active Power Filter Control Based on Multiresolution Analysis
نویسندگان
چکیده
The paper presents an active power filter control method. The reference signal is generated in the stationary reference frame α-β using multiresolution analysis and the controllers used are P-resonant controllers, suitable for this particular application due to the fact that the steady-state error is zero for sinusoidal references with the frequency corresponding to the resonant frequency of the controller.
منابع مشابه
Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملPerformance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter
This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...
متن کاملSliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملA Closed-Loop Selective Harmonic Compensation for Active Filters
This paper proposes a control algorithm for parallel active power filters, based on current-controlled pulsewidth-modulated converters, which allows precise compensation of selected harmonic currents produced by distorting loads. The approach is based on the measurement of line currents and performs the compensation of the selected harmonics using closed-loop synchronous frame controllers. Than...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007