Computed tomographic virtual colonoscopy computer-aided polyp detection in a screening population.
نویسندگان
چکیده
BACKGROUND & AIMS The sensitivity of computed tomographic (CT) virtual colonoscopy (CT colonography) for detecting polyps varies widely in recently reported large clinical trials. Our objective was to determine whether a computer program is as sensitive as optical colonoscopy for the detection of adenomatous colonic polyps on CT virtual colonoscopy. METHODS The data set was a cohort of 1186 screening patients at 3 medical centers. All patients underwent same-day virtual and optical colonoscopy. Our enhanced gold standard combined segmental unblinded optical colonoscopy and retrospective identification of precise polyp locations. The data were randomized into separate training (n = 394) and test (n = 792) sets for analysis by a computer-aided polyp detection (CAD) program. RESULTS For the test set, per-polyp and per-patient sensitivities for CAD were both 89.3% (25/28; 95% confidence interval, 71.8%-97.7%) for detecting retrospectively identifiable adenomatous polyps at least 1 cm in size. The false-positive rate was 2.1 (95% confidence interval, 2.0-2.2) false polyps per patient. Both carcinomas were detected by CAD at a false-positive rate of 0.7 per patient; only 1 of 2 was detected by optical colonoscopy before segmental unblinding. At both 8-mm and 10-mm adenoma size thresholds, the per-patient sensitivities of CAD were not significantly different from those of optical colonoscopy before segmental unblinding. CONCLUSIONS The per-patient sensitivity of CT virtual colonoscopy CAD in an asymptomatic screening population is comparable to that of optical colonoscopy for adenomas > or = 8 mm and is generalizable to new CT virtual colonoscopy data.
منابع مشابه
A Review of Current Computer Aided Diagnosis Systems for Polyp Detection in Virtual Colonoscopy
The potential of Computer Aided Diagnosis (CAD) has been exploited lately in order to assist the doctors in carrying out the inspection of lengthy videos from virtual colonoscopy. Colonic polyps are known precursors of the colon cancer, which has been the third mostly diagnosed form of cancer. In this paper, we discuss the most important parameters used for evaluation of CAD systems for polyp d...
متن کاملUsing Optical Flow Fields for Polyp Detection in Virtual Colonoscopy
Since the introduction of Computed Tomographic Colonography (CTC), research has mainly focused on visualization and navigation techniques. Recently, efforts have shifted towards computer aided detection (CAD) of polyps. We propose a new approach to CAD in CT images that attempts to model the way a radiologist recognizes a polyp using optical flow fields (OFF). Features extracted from OFFs are u...
متن کاملA Complete System for Polyps Flagging in Virtual Colonoscopy
Computer tomographic colonography, combined with computer-aided detection, is a promising emerging technique for colonic polyp analysis. We present a complete pipeline for polyp flagging based on a simple segmentation technique that enhances polyps, a multi-scale candidate polyp delineation, and new texture and geometric features that consider both the information in the candidate polyp locatio...
متن کاملAbstract-Papers up to 4 pages should be submitted using this format
bstractMost current computer-aided detection (CAD) gorithms for the fully automatic detection of colonic polyps om 3D CT data suffer from high false positive rates. We eveloped and evaluated a post-processing algorithm to decrease e false positive rate of such a method. Our method attempts to odel the way a radiologist recognizes a polyp while scrolling a oss-sectional plane through 3D CT data ...
متن کاملComputer-aided detection for virtual colonoscopy
Colon cancer is one of the leading causes of cancer deaths in the developed countries. Most colon cancers can be prevented if precursor colon polyps are detected and removed. Virtual colonoscopy, or CT colonography, has shown promise to be the future screening tool for polyp detection, with a number of studies performed at academic institutions showing high sensitivity and specificity. Two main...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gastroenterology
دوره 129 6 شماره
صفحات -