A Comparison of Two Techniques for Ultrasound-guided Caudal Injection: The Influence of the Depth of the Inserted Needle on Caudal Block
نویسندگان
چکیده
BACKGROUND Caudal epidural injections have been commonly performed in patients with low back pain and radiculopathy. Although caudal injection has generally been accepted as a safe procedure, serious complications such as inadvertent intravascular injection and dural puncture can occur. The present prospective study was designed to investigate the influence of the depth of the inserted needle on the success rate of caudal epidural blocks. METHODS A total of 49 adults scheduled to receive caudal epidural injections were randomly divided into 2 groups: Group 1 to receive the caudal injection through a conventional method, i.e., caudal injection after advancement of the needle 1 cm into the sacral canal (n = 25), and Group 2 to receive the injection through a new method, i.e., injection right after penetrating the sacrococcygeal ligament (n = 24). Ultrasound was used to identify the sacral hiatus and to achieve accurate needle placement according to the allocated groups. Contrast dyed fluoroscopy was obtained to evaluate the epidural spread of injected materials and to monitor the possible complications. RESULTS The success rates of the caudal injections were 68.0% in Group 1 and 95.8% in Group 2 (P = 0.023). The incidences of intravascular injections were 24.0% in Group 1 and 0% in Group 2 (P = 0.022). No intrathecal injection was found in either of the two groups. CONCLUSIONS The new caudal epidural injection technique tested in this study is a reliable alternative, with a higher success rate and lower risk of accidental intravascular injection than the conventional technique.
منابع مشابه
Ultrasound-guided Caudal Epidural Injection
To the Editor:—I read with interest the article “Ultrasound Guidance in Caudal Epidural Needle Placement” by Chen et al. However, I have a couple of points to raise. The author’s assertion that the application of ultrasonography to locate the sacral hiatus for caudal epidural injections has not been described is inaccurate. The footprint property of the transducer is not mentioned in the articl...
متن کاملUltrasound-guided Caudal Epidural Injection
To the Editor:—I read with interest the article “Ultrasound Guidance in Caudal Epidural Needle Placement” by Chen et al. However, I have a couple of points to raise. The author’s assertion that the application of ultrasonography to locate the sacral hiatus for caudal epidural injections has not been described is inaccurate. The footprint property of the transducer is not mentioned in the articl...
متن کاملCaudal Epidural Steroid Injections in Postlaminectomy Patients: Comparison of Ultrasonography and Fluoroscopy.
AIM To compare the results of ultrasound and fluoroscopy guided caudal epidural steroid injections in postlaminectomy patients. MATERIAL AND METHODS Thirty postlaminectomy patients were randomly divided into two groups, Group I (n=15) received ultrasound-guided and Group II (n=15) received fluoroscopy-guided caudal epidural local anesthetic and steroid injection. Time of block for each patien...
متن کاملComparison the effect of epidural steroid injection by Caudal and Lumbar methods for controlling the radicular pain of lower extremity
Aims and background: Chronic low back pain is one of the common causes of patients referring to specialized and general medical clinics. The positive effect of Epidural Steroid injection has been proven in relieving pain in these patients. In this study, the epidural effects of methylprednisolone acetate in these two methods of Caudal and Lumbar were compared. Materials and Methods: In thi...
متن کاملDisadvantages of ultrasound guidance in caudal epidural needle placement.
To the Editor:—I read with interest the article “Ultrasound Guidance in Caudal Epidural Needle Placement” by Chen et al. However, I have a couple of points to raise. The author’s assertion that the application of ultrasonography to locate the sacral hiatus for caudal epidural injections has not been described is inaccurate. The footprint property of the transducer is not mentioned in the articl...
متن کامل