Trace Element Profiling of Gunshot Residues by PIXE and SEM-EDS: A Comparative Study

نویسندگان

  • M. Webb
  • D. Cox
  • K. J. Kirkby
  • C. Jeynes
چکیده

We critically compare particle induced X-ray emission (PIXE) on the ion microprobe with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDS) for the characterisation of gunshot residues (GSR). Samples of gunshot residue from several different firearms were collected. Individual particles of GSR were analysed by SEM-EDS using a 30keV electron beam focussed to ~10nm and PIXE using a 2.5MeV proton beam focussed to ~4 microns. PIXE revealed trace or minor elements undetectable by SEM-EDS, and could discriminate GSR indistinguishable by SEM-EDS. Published as: M.J.Bailey, K.J.Kirkby, C.Jeynes, X-Ray Spectrometry, 38 (2009) 190-194; http://dx.doi.org/10.1002/xrs.1142 Introduction In order to demonstrate that a suspect in a criminal investigation has fired a weapon, police authorities routinely take swabs from the clothing, skin and hair of the suspect and use electron microscopy to search for gunshot residue (GSR) particles on the swabs. These particles are condensation products of the high temperature, high pressure reactions that occur when a firearm is fired and are known to be deposited at the crime scene and on the shooter [1]. The particles are made up of material from the primer, bullet, bullet jacket, cartridge casing and the gun barrel, are spherical, and are of the order of a few microns in diameter. There are several types of particle that are characteristic of gunshot residue, including those containing Pb, Ba and Sb [2]. In case work, it is highly desirable to be able to discriminate GSR from different sources to rule out possible contamination and to strengthen the link between a suspect and a crime scene. It is known that GSR varies in composition and morphology in accordance with the type of firearm that has produced it. The UK Metropolitan Police have developed a categorisation system for gunshot residues, putting them in 35 different categories in accordance with their morphology and chemical composition. It is accepted that the chemical composition of GSR is a better indicator of its provenance than morphology [3], [5]. The technique of choice amongst police institutions for the analysis of GSR is scanning electron microscope energy dispersive X ray spectrometry (SEM-EDS) since the technique is widely available, relatively cheap and can be automated. EDS also offers the advantage of imaging the particles as well as determining their chemical composition, and is nondestructive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new quantitative method for gunshot residue analysis by ion beam analysis.

Imaging and analyzing gunshot residue (GSR) particles using the scanning electron microscope equipped with an energy dispersive X-ray spectrometer (SEM-EDS) is a standard technique that can provide important forensic evidence, but the discrimination power of this technique is limited due to low sensitivity to trace elements and difficulties in obtaining quantitative results from small particles...

متن کامل

The concentration of heavy trace elements in pigment and cholesterol humangallstones: Comparative studies by PIXE analysis.

Background: The method of proton induced X-ray emission (PIXE) has been widely used as a sensitive technique to trace elemental analysis in both biological and medical fields. The sensitivity of this powerful method is in the order of ppm .The aim of this work is to analyze structural composition of 4 heavy trace elements with Z greater than 24 (Mn, Fe, Cu, Zn) in two kinds of gallstones and to...

متن کامل

C3an00597f 4649..4655

Imaging and analyzing gunshot residue (GSR) particles using the scanning electron microscope equipped with an energy dispersive X-ray spectrometer (SEM-EDS) is a standard technique that can provide important forensic evidence, but the discrimination power of this technique is limited due to low sensitivity to trace elements and difficulties in obtaining quantitative results from small particles...

متن کامل

Accurate determination of the Ca : P ratio in rough hydroxyapatite samples by SEM - EDS , PIXE and RBS – a comparative study

PACS: 68.35.Ct Interface structure and roughness 68.55.Ln Defects and impurities: doping, distribution, concentration, etc 81.70.Jb Chemical composition analysis, chemical depth and dopant profiling 82.80.Ej X-ray, Mössbauer, and other γ-ray spectroscopic analysis methods 82.80.Yc Rutherford backscattering (RBS), and other methods of chemical analysis 83.80.Fg Granular solids 83.80.Lz Physiolog...

متن کامل

Micro-pixe analysis in invasive ductal carcinoma tissues after treatment of astaxanthin

Background: Trace elements play an important role in a number of biological processes. Astaxanthin (ASX), a carotoid pigment found in certain marine plant and animals, has shown anti cancer and anti free radical properties. This work intended to understand the effect of Astaxanthin in breast cancer (invasive ductal carcinoma, IDC) by using micro-pixe method. For this aim the concentratio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014