Carbon Films and Specimen Stability
نویسنده
چکیده
In recent years a subject which has received little attention is the question of motion of the specimen relative to the objective lens of the electron microscope. In ordinary electron microscopy, where resolutions better than 30 A are not required, one can tolerate drift of the object (during a 5 second exposure of the plate) of perhaps 1 to 3 A per second, while for high resolution microscopy this figure may drop as low as 0.2 to 0.6 A per second. When we consider that the distance between adjacent atoms of many substances is on the order of 1 A, it is clear that our stability requirements are rather stringent. For purposes of analysis we can find two general sources of specimen drift: motion of the specimen holder arising in the stage mechanism and motion of the specimen relative to the grid. We will consider these in order. Inherent in the design of any useable stage mechanism is its ability to move the specimen over distances hundreds of thousands of times greater than the size of objects one desires to resolve. Any part of this mechanism subject to mechanical relaxation or to sensitivity to vibration may cause undesired motion of the specimen. Proper adjustment of the stage mechanism will minimize the mechanical problems mentioned above, but may not be permanent. There remains, in addition, the long mechanical pathway between the specimen and the objective which is subject to thermal effects during warmup, drafts around the microscope, etc. Although the stage may be perfectly stable in one position, this is no guarantee that it is stable in another position. For this reason it is d~Scult to be certain that the mechanism is operating properly. Operating practice leading to consistently good results from the microscope requires certainty on this point. In addition, if other sources of image drift, such as drift in the power supplies, are present as well, one is in doubt as to where to look for the trouble. These points, in my opinion, are strong arguments for eliminating insofar as possible all sources of stage drift. The device to be described provides an arrangement whereby the chances for motion of the specimen holder are very substantially reduced. While this device has been primarily designed for the RCA types EMU-1 and -2 microscopes, it probably can be adapted to certain other instruments as well. Essentially, the specimen holder is arranged so that it rests on top of the objective polepiece and is in contact with the stage only when it is being moved. Text-fig. 1 shows how this is achieved. 31
منابع مشابه
Effect of surface roughness of carbon support films on high- resolution electron diffraction of two-dimensional protein crystals
The surface roughness of carbon films, which are used as a specimen support in high-resolution electron microscopy, has been investigated by atomic force microscopy. Carbon films were prepared by evaporating carbon onto mica. We found that the carbon surface that had been in contact with the mica was between 3 and 9 times smoother than the surface which had faced the carbon source. Surfaces of ...
متن کاملCost Effective and Scalable Synthesis of MnO2 Doped Graphene in a Carbon Fiber/PVA: Superior Nanocomposite for High Performance Flexible Supercapacitors
In the current study, we report new flexible, free standing and high performance electrodes for electrochemical supercapacitors developed througha scalable but simple and efficient approach. Highly porous structures based on carbon fiber and poly (vinyl alcohol) (PVA) were used as a pattern. The electrochemical performances of Carbon fiber/GO-MnO2/CNT supercapacitors were characteriz...
متن کاملPhotogenerated free carrier dynamics in metal and semiconductor single-walled carbon nanotube films.
Time-resolved THz spectroscopy (TRTS) is employed to study the photogenerated charge-carrier dynamics in transparent films of single-walled carbon nanotubes (SWNTs). Two films were investigated: a film with 94% semiconducting-type tubes (s-SWNTs) and a film with only 7% s-SWNT and 93% metal-type tubes (m-SWNTs). We conclude that charge-carriers are generated with >60% yields at low light intens...
متن کاملThe Preparation of Carbon Films for Electron Microscopy
Carbon films prepared by the method of Bradley (1) are commonly used as specimen supports in preference to plastic films because they are more stable under electron bombardment. Their preparation involves, however, a number of operations, in each of which there is some risk of contamination. Techniques have been developed which reduce the number of operations, but they are useful only in the st...
متن کاملOptimized Conditions for Catalytic Chemical Vapor Deposition of Vertically Aligned Carbon Nanotubes
Here, we have synthesized vertically aligned carbon nanotubes (VA-CNTs), using chemical vapor deposition (CVD) method. Cobalt and ethanol are used as the catalyst and the carbon source, respectively. The effects of ethanol flow rate, thickness of Co catalyst film, and growth time on the properties of the carbon nanotube growth are investigated. The results show that the flow rate of ethanol and...
متن کاملThickness, stability and contact angle of liquid films on and inside nanofibres, nanotubes and nanochannels.
While the stability of liquid films on substrates is a classical topic of colloidal science, the availability of nanostructured materials, such as nanotubes, nanofibres and nanochannels, has raised the question of how the stability of liquid films and their wetting behaviour is affected by nanoscale confinement. This paper will present the conditions for the stability of liquid films on and ins...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Biophysical and Biochemical Cytology
دوره 2 شماره
صفحات -
تاریخ انتشار 1956