Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component.

نویسندگان

  • Martin Clauss
  • Catherine Van Der Straeten
  • Marc Goossens
چکیده

Early subsidence >1.5 mm is considered to be a predictive factor for later aseptic loosening of the femoral component following total hip arthroplasty (THA). The aim of this study was to assess five-year subsidence rates of the cementless hydroxyapatite-coated twinSys stem (Mathys Ltd., Bettlach, Switzerland).This prospective single-surgeon series examined consecutive patients receiving a twinSys stem at Maria Middelares Hospital, Belgium. Patients aged >85 years or unable to come to follow-up were excluded. Subsidence was assessed using Ein Bild Roentgen Analyse--Femoral Component Analysis (EBRA-FCA). Additional clinical and radiographic assessments were performed. Follow-ups were prospectively scheduled at two, five, 12, 24, and 60 months.In total, 218 THA (211 patients) were included. At five years, mean subsidence was 0.66 mm (95% CI: 0.43-0.90). Of the 211 patients, 95.2% had an excellent or good Harris Hip Score. There were few radiological changes. Kaplan-Meier analysis indicated five-year stem survival to be 98.4% (95% CI: 97.6-100%).Subsidence levels of the twinSys femoral stem throughout the five years of follow-up were substantially lower than the 1.5 mm level predictive of aseptic loosening. This was reflected in the high five-year survival rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty

BACKGROUND Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that are designed for cementless fixation. We evaluated the performance of and periprosthetic bone response to a tapered, titanium, hydroxyapatite (HA)-coated femoral hip prosthesis at a minimum of 7...

متن کامل

A new uncemented hydroxyapatite-coated femoral component for the treatment of femoral neck fractures: two-year radiostereometric and bone densitometric evaluation in 50 hips.

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the fem...

متن کامل

Uncemented fully hydroxyapatite-coated hip stem for intracapsular femoral neck fractures in osteoporotic elderly patients: a multicenter study

There is still debate over the limits of age and bone stock quality of patients on whom to use an un-cemented straight stem coated with hydroxyapatite (HA). We studied a group of 244 patients with a displaced intracapsular fracture of the femoral neck who underwent cementless hemiarthroplasty or total hip arthroplasty. 143 patients were reviewed at the two-year follow up. A fully HA-coated stem...

متن کامل

Minimum 5-year follow-up for primary THA using a tapered, proximally coated cementless stem.

The purpose of this study was to assess the survivorship of a proximally coated, cementless femoral stem used for total hip arthroplasty at a minimum 5-year follow-up by assessing clinical outcomes and implant survival. A total of 936 primary total hip arthroplasties were performed in 854 patients by 3 high-volume surgeons between 2001 and 2007. Patients included 385 men and 469 women with a me...

متن کامل

Hydroxyapatite-coated versus grit-blasted femoral stems. a prospective, randomised study using EBRA-FCA.

We have carried out a prospective, randomised study designed to compare the long-term stability of the stem of cementless femoral implants with differing surface configurations. A total of 50 hips (46 patients) was randomised into two groups, according to whether the medullary stem had been grit blasted (GB) or coated with hydroxyapatite (HA). Both femoral prostheses were of the same geometrica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hip international : the journal of clinical and experimental research on hip pathology and therapy

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2014