Determination of Boron, Phosphorus, and Molybdenum Content in Biosludge Samples by Microwave Plasma Atomic Emission Spectrometry (MP-AES)

نویسندگان

  • Vudagandla Sreenivasulu
  • Mohammad Asif
چکیده

A novel analytical method for accurate determination of boron (B), phosphorous (P), and molybdenum (Mo) content in biosludge samples based on a relatively recent analytical technique, microwave plasma atomic emission spectrometry (MP-AES), is developed in the present work. Microwave assisted acid digestion method is utilized to extract B, P, and Mo from biosludge. To demonstrate the reliability and accuracy of the present MP-AES method, its results are compared with those obtained using two well-established techniques, i.e., flame atomic absorption spectrometry (FAAS) and inductively coupled plasma optical emission spectrometry (ICP-OES). Matrix variation in the MP-AES technique is found to result in minimal changes. Precision and accuracy of the developed method are demonstrated using replicate analyses of certified sewage sludge reference material, EnviroMAT (BE-1). The limit of quantification and detection of B, P, and Mo in the extracts are determined; the linear regression coefficient was greater than 0.998 for all the three techniques. Analytical wavelengths are selected according to the sensitivity and interference effects. The results obtained in this work demonstrate the potential of MP-AES technique for the determination of B, P, and Mo content in biosludge, which achieved lower detection limits, higher accuracy, and better reproducibility as compared to other techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct analysis of Cr , Ni , Pb and V in ethanol fuel by Microwave Plasma - Atomic Emission Spectrometry Application note Authors

A simple dilute-and-shoot procedure for determination of Cr, Ni, Pb and V in ethanol fuel by Microwave Plasma-Atomic Emission Spectrometry (MP-AES) is proposed. Samples were easily prepared and neither special nor expensive gases were needed for performing analyses. All limits of detection from 0.3–40 μg/L were compatible with the requirements taken into account when considering fuel impacts on...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Microwave Digestion and Ultrasonic Nebulization for Determination of Boron in Animal Tissues by Inductively Coupled Plasma Atomic Emission Spectrometry With Internal Standardization and Addition of Mannitol

Determinations of boron in animal tissues were performed by introduction technique for the determination of trace levels of B by ICP-AES. inductively coupled plasma atomic emission spectrometry (ICP-AES) with an ultrasonic nebulizer. The method is based The accurate determination of B in animal tissues has proven di cult because of the very low concentrations found in some on the microwave dige...

متن کامل

Analysis of aluminum in beverages using the Agilent 4100 Microwave Plasma - Atomic Emission Spectrometer ( MP - AES ) Application note

Aluminum present in a beverages can affect the taste. This application note describes the determination of aluminum in beverages using an Agilent 4100 MP-AES. Beverages contain a variety of matrix constituents, including salt, sugar, and alcohol. A study was performed to determine how these matrix constituents affect aluminum measurements, and what could be done to reduce such effects. It was d...

متن کامل

Screening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology

Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017