Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content.
نویسندگان
چکیده
PURPOSE To investigate reproducibility of proton magnetic resonance spectroscopy ((1)H-MRS) to measure hepatic triglyceride content (HTGC). MATERIALS AND METHODS In 24 subjects, HTGC was evaluated using (1)H-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of (1)H-MRS in subjects with fatty liver. We also studied within liver variability and within day reproducibility. Reproducibility was assessed by coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC). RESULTS The CV of between weeks reproducibility was 9.5%, with a RC of 1.3% HTGC (ICC 0.998). The CV in fatty livers was 4.1%, with a RC of 1.3% HTGC (ICC 0.997). Within day CV was 4.5%, with a RC of 0.4% HTGC (ICC 0.999). CV for within liver variability was 14.5%. CONCLUSION Reproducibility of (1)H-MRS to measure HTGC for "between-weeks" measurements and in fatty livers is high, which is important for follow-up studies. Within liver variability displays a larger variation, meaning that liver fat is not equally distributed and during consecutive measurements the same voxel position should be used.
منابع مشابه
Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملReproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and 1H magnetic resonance spectroscopy at 3.0 Tesla.
OBJECTIVES The reproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and H magnetic resonance (MR) spectroscopic imaging was assessed on a clinical 3.0 T MR system. MATERIALS AND METHODS Repeated measurements in 10 healthy volunteers were used to establish the reproducibility of quantitative measures derived from different quantitative MR techniques, namely the T2...
متن کاملNoninvasive quantification of hepatic steatosis in rats using 3.0 T 1H-magnetic resonance spectroscopy.
PURPOSE To assess the accuracy of noninvasive 3.0 T (1)H-magnetic resonance spectroscopy ((1)H-MRS) in an experimental steatosis model for the discrimination of clinically relevant macrovesicular steatosis degrees and to evaluate three different (1)H-MR spectrum-based fat quantification methods. MATERIALS AND METHODS Steatosis was induced in rats by a methionine/choline-deficient diet for 0-5...
متن کاملAssessment of iron deposition in the heart in sickle cell patients using 3.0 Tesla cardiovascular magnetic resonance
This study investigates the role of 3.0T R2* imaging for measuring cardiac iron overload. Experiments were conducted on calibrated phantoms and sickle cell disease (SCD) patients. R2* imaging at 3.0T enabled assessment of wide range of iron concentrations. R2* values at 3.0T were about double of those at 1.5T. Myocardial R2* showed weak and strong correlations with hepatic R2* and serum ferriti...
متن کاملRapid Quantification of Myocardial Lipid Content in Humans Using Single Breath-Hold 1H MRS at 3 Tesla
A rapid, proton magnetic resonance spectroscopy method to evaluate human myocardial lipid levels in a single breath-hold at 3 T using a commercial whole-body system is presented. During a 10 s breath-hold, water unsuppressed and suppressed spectra were acquired by two phased array coils using a short-echo time spectroscopic stimulated echo (STEAM) sequence electrocardiogram-triggered to mid-dia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2009