Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

نویسندگان

  • D de Rijke
  • H J Kreutzer
چکیده

We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-starch technique. The method for total amylase appeared to be rapid and precise (CV = 4%) and results correlated well with the chromogenic method. Samples with activities up to 3000 arb. units/L can be analyzed without dilution. Glucose and pyruvate interfere with the assay, but hemoglobin and bilirubin do not. Pancreatic (P) and salivary (S) isoamylase activity can be determined with acceptable precision (CVP = 8%, CVS = 10%) by an automated routine procedure with commercially available reagents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preferential salivary-type hypoamylasemia in obese children.

Serum levels of total amylase, pancreatic type (P-type) isoamylase, and salivary type (S-type) isoamylase were measured in obese children (153 subjects; mean age, 10.1 years old; 86 boys and 67 girls) before and after weight reduction therapy. Serum amylase activities were determined using p-nitrophenylmaltoheptaoside as a substrate, with or without an antibody added to inhibit the S-type isoam...

متن کامل

Evaluation of a new inhibitor test for isoamylase on Hitachi 705 analyser.

We describe a simple and rapid method for measuring pancreatic and salivary type amylases using the Hitachi 705 analyser. The determination is based on the inhibition of salivary amylase using an inhibitor isolated from wheat germ. The precision of the proposed method was very good: within-day precision varied from 0.4 to 2.5% (CV) and day-to-day precision from 2.2 to 3.7% (CV). The new applica...

متن کامل

Hyperamylasaemia after duodenoscopy and retrograde cholangiopancreatography.

The salivary and pancreatic isoamylases of serum were determined separately in 234 cases of duodenoscopy and retrograde cholangiopancreatography. Successful pancreatic opacification was associated with pathologically high pancreatic serum amylase activities in 60% of the cases. Extensive opacification was associated with large increases of pancreatic serum isoamylases, the maximal rise recorded...

متن کامل

Measuring carboxypeptidase A activity with a centrifugal analyzer: analytical and clinical considerations.

This adaptation of a commercially available kit for automated measurement of carboxypeptidase A (CPA; EC 3.4.17.1) activity in serum with the Cobas Bio centrifugal analyzer extends the linear range to an activity concentration of 82 U/L. Results obtained by the described method correlated closely (r = 0.98) with those by the manual kit method. The reference interval for 150 apparently normal in...

متن کامل

Measurement of total protein and albumin in serum with a centrifugal analyzer.

In most clinical chemistry laboratories, mechanized procedures are essential for measurement of serum total protein and albumin. The biuret reaction is well established as the most practical approach to mechanized total protein measurements (1-4); albumin has posed a more difficult problem, with several procedures being proposed, some of which have involved salt fractionation (1-4), electrophor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 1983