Creation and measurement of broadband squeezed vacuum from a ring optical parametric oscillator.
نویسندگان
چکیده
We report a 65 MHz-bandwidth triangular-shaped optical parametric oscillator (OPO) for squeezed vacuum generation at 860 nm. The triangle structure of our OPO enables the round-trip length to reach 45 mm as a ring cavity, which provides a counter circulating optical path available for introducing a probe beam or generating another squeezed vacuum. Hence our OPO is suitable for the applications in high-speed quantum information processing where two or more squeezed vacua form a complicated interferometer, like continuous-variable quantum teleportation. With a homemade, broadband and low-loss homodyne detector, a direct measurement shows 8.4 dB of squeezing at 3 MHz and also 2.4 dB of squeezing at 100 MHz.
منابع مشابه
Optimization and transfer of vacuum squeezing from an optical parametric oscillator
We report the observation of more than 7 dB of vacuum squeezing from a below-threshold optical parametric oscillator (OPO). We discuss design criteria and experimental considerations for its optimization and demonstrate that the vacuum squeezing can be electro-optically transferred to a bright beam using a feed-forward loop. This is compared with the bright intensity squeezed beam generated by ...
متن کاملParametric Oscillation with Squeezed Vacuum Reservoirs
Employing the quantum Hamiltonian describing the interaction of two-mode light (signalidler modes) generated by a nondegenerate parametric oscillator (NDPO) with two uncorrelated squeezed vacuum reservoirs (USVR), we derive the master equation. The corresponding Fokker-Planck equation for the Q-function is then solved employing a propagator method developed by K. Fesseha [J. Math. Phys. 33 2179...
متن کاملGeneration and direct detection of broadband mesoscopic polarization-squeezed vacuum.
Using a traveling-wave optical parametric amplifier with two orthogonally oriented type-I BBO crystals pumped by picosecond pulses, we generate vertically and horizontally polarized squeezed vacuum states within a broad frequency-angular range. Depending on the phase between these states, fluctuations in one or another Stokes parameter are suppressed below the shot-noise limit. Because of the l...
متن کاملGeneration of a squeezed vacuum resonant on a rubidium D1 line with periodically poled KTiOPO4.
We report the generation of a continuous-wave squeezed vacuum resonant on the Rb D1 line (795 nm) using periodically poled KTiOPO4 (PPKTP) crystals. With a frequency doubler and an optical parametric oscillator based on PPKTP crystals, we observed a squeezing level of -2.75+/-0.14 dB and an antisqueezing level of +7.00+/-0.13 dB. This system could be utilized for demonstrating storage and retri...
متن کاملImproving quantum-noise reduction with spatially multimode squeezed light
We consider the squeezed vacuum state emitted by a degenerate optical parametric oscillator below threshold. We show, by using a confocal cavity and an appropriate matching lens, that the observed level of squeezing can become largely independent of the spatial intensity configuration of the local-oscillator field. © 1997 Optical Society of America [S0740-3224(97)01002-3] PACS number(s): 42.50....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 24 25 شماره
صفحات -
تاریخ انتشار 2016