Acute Metallosis Following Total Knee Replacement – A Case Report

نویسندگان

  • Karl C. Klontz
  • William I Smith
  • Klontz Jonathan C.
چکیده

INTRODUCTION Metallosis involving the knee joint most often results from metal-on-metal contact late in the life of a failing implant following polyethylene wear. We report a case of acute metallosis following knee arthroplasty in a previously healthy 59-year old male. CASE REPORT In June 2011, the patient underwent left knee arthroplasty for severe osteoarthritis with necrosis and bone edema in the medial femoral condyle and tibial plateau. Nine months later, because of persistent pain and swelling in the joint, revision arthroplasty was undertaken along with partial synovectomy. Examination revealed pristine prosthetic implants in the absence of loose fragments of bone or glue. Synovial pathology exhibited marked chronic inflammation and hyperplasia with extensive finely granular foreign material resembling metallic debris. Laboratory analysis of synovium revealed a predominance of iron, the principal component of the saw blades. CONCLUSION We hypothesize the patient experienced acute metallosis resulting from deposition of metallic fragments from three saw blades used during arthroplasty. We believe the increased density of the patient's bone that required use of multiple blades may have resulted, in part, from heavy lifting the patient partook in during the two years preceding arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallosis Presenting as Knee Pain 26 years after Primary Total Knee Arthroplasty

INTRODUCTION Metallosis occurs when periprosthetic soft tissues, synovium, and/or bone is infiltrated by metallic debris secondary to metal-on-metal wear. This debris can cause a chronic inflammatory reaction leading to joint instability, pain, and swelling, and may cause osteolysis, implant looseningand ultimately implant failure. CASE REPORT An 81 year old female, with a history of primary ...

متن کامل

Wear debris pseudotumor following total knee arthroplasty: a case report

INTRODUCTION In patients who have undergone a total joint replacement, any mass occurring in or adjacent to the joint needs thorough investigation and a wear debris-induced cyst should be suspected. CASE PRESENTATION An 81-year-old man presented with a painful and enlarging mass at the popliteal fossa and calf of his right knee. He had had a total right knee replacement seven years previously...

متن کامل

Metallosis in an apparently well fixed total knee replacement

One of the findings of prosthetic failure seen either on pre operative radiograph or at surgery is metallosis. To our knowledge, this has not been described in an apparently well-fixed noninfected prosthetic joint. Metallosis can be due to polyethylene bearing wear resulting in metal on metal wear and has been seen with macro motion of prosthesis against underlying cement or bone1. CASE REPORT ...

متن کامل

Early failure with massive metallosis and posteromedial wear following atraumatic anterior cruciate ligament rupture after medial unicompartmental knee arthroplasty

Severe metallosis following medial unicompartmental knee arthroplasty (UKA) is relatively rare. It is usually due to long-standing wear of the polyethylene component, resulting in frictional wear between the femoral and tibial metallic components. Biomechanical and cadaveric studies have shown the effects of anterior cruciate ligament (ACL) transection following medial UKA. We describe a case o...

متن کامل

Delamination of tantalum porous coating from a TKA due to regional dissemination of debris.

Metallic debris from metal-on-metal bearings is a recognized mode of failure that may lead to implant loosening and periprosthetic soft tissue reactions. The sequelae of metallosis have been most commonly reported with respect to total hip arthroplasty. The authors report a rare case of metallosis following a hybrid metal-on-polyethylene total knee arthroplasty that used a porous tantalum tibia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014