Evaluation of diagnostic serological results in cases of suspected primary syphilis infection.

نویسندگان

  • Beau Gratzer
  • Daniel Pohl
  • Anna L Hotton
چکیده

BACKGROUND Reverse sequence screening for syphilis, in which an automatable treponemal assay (enzyme immunoassay [EIA]/chemiluminescence assay [CIA]) is performed first and followed by a nontreponemal test for reactive specimens, has been used increasingly in the United States. The EIA is objective, efficient, and believed to be more sensitive than the rapid plasma reagin (RPR) because treponemal antibodies appear before nontreponemal antibodies. We sought to compare the sensitivity of a commonly used EIA, the Trep-Sure EIA (TS-EIA), to the RPR in cases of suspected primary syphilis infection in our clinic. METHODS A retrospective medical record review of patients with sexually transmitted infection clinic visits from January 2009 to December 2011 was conducted, and 52 patients met the following inclusion criteria: suspected primary syphilis symptoms, at least 1 positive syphilis test result at visit, and no history of syphilis. Sensitivity analyses compared the TS-EIA and RPR, using the reference standard of concordantly positive/reactive TS-EIA/RPR or positive fluorescent treponemal antibody absorption test (FTA-ABS) result. We considered equivocal TS-EIA results to be positive for sensitivity calculations because such results typically reflex to additional testing and therefore may still result in identifying new infections. RESULTS Twenty-eight (53.8%) of the 52 patients had a positive or equivocal TS-EIA. Twenty-five (89.3%) of those were RPR reactive; the remaining 3 (10.7%) were RPR nonreactive, FTA-ABS positive. Forty patients (76.9%) had a positive RPR, including 15 patients (37.5%) with negative TS-EIA results; all 15 were FTA-ABS positive. Nine additional patients were TS-EIA negative and RPR nonreactive but had a positive FTA-ABS result. The RPR was significantly more sensitive than the EIA (76.9% vs. 53.8%, P = 0.005). Trep-Sure EIA positivity was also significantly associated with higher median RPR titer (P = 0.011). CONCLUSIONS Use of the TS-EIA may result in underdetection of primary syphilis compared with the RPR. Further evaluation of the sensitivity of the TS-EIA in high-morbidity settings is warranted before the adoption of reverse sequence screening algorithms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serological and Molecular Detection of Akabane Virus in Iran

The present study was conducted on sixty healthy female domestic ruminants that suffered from still births or abortion, to find sero-positive cases and also to determine the probable role of uterine tissue in diagnosis of akabane viral infection and viral persistency. Because of this, a serological test (ELISA) and molecular (RT-PCR) diagnostic methods were used to find the seropositive cases a...

متن کامل

Toxoplasmosis Seroepidemiology in Serum of Suspected Patients Referring to Medical Lab, 2013

Introduction: Toxoplasmosis is Zoonoses among humans and animals with cosmopolitan distribution. Acquired form of the disease often has no symptoms or discomfort of swollen lymph nodes and associated Chorioretinitis. The congenital form of the disease from mother to fetus via the placenta is delivered. Congenital infection may cause abortion or damage the central nervous system and eye disorde...

متن کامل

Evaluation of Clinical and Laboratory Data in Patients with Recurrent Infections and Suspected Immunodeficiency

Background: Frequent infections is among the most frequent clinical dilemmas for primary care physicians. Immunodeficiency disorders are a heterogeneous group of illnesses that predispose patients to the recurrent infections, autoimmunity and malignancies. The aim of this study was to evaluate the clinical and laboratory data collected for the final diagnosis of patients referred with recurrent...

متن کامل

Evaluation of Human Serological Response to Recombinant TB10.4 Antigen of Mycobacterium tuberculosis

  Introduction: Development of effective immunodiagnostic methods for detection of Mycobacterium tuberculosis infection is crucial. Serodiagnostic methods, based on antibody response to specific antigens could provide promising approaches for rapid, economical and easy to perform diagnostic tests which are crucial for tuberculosis (TB) control. In this study, the level of IgG antibody responses...

متن کامل

A longitudinal evaluation of Treponema pallidum PCR testing in early syphilis

BACKGROUND Syphilis is a growing public health problem among men who have sex with men (MSM) globally. Rapid and accurate detection of syphilis is vital to ensure patients and their contacts receive timely treatment and reduce ongoing transmission. METHODS We evaluated a PCR assay for the diagnosis of Treponema pallidum using swabs of suspected early syphilis lesions in longitudinally assesse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sexually transmitted diseases

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 2014