Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column Authors
نویسندگان
چکیده
An Agilent ZORBAX sub-2 μm Rapid Resolution High Definition (RRHD) 300SB-C8 reversed-phase column was used under optimized chromatographic conditions for delivering highly resolved ultra fast separations of reduced and alkylated monoclonal antibodies. The StableBond C8 phase and RRHD column technology, in combination with robust gradient elution conditions enabled efficient, fast, and effective separation of light chain and two heavy chain monoclonal antibody variants in under 4 minutes. Additionally, alternate mobile phase compositions were employed, making separations flexible for ultra fast LC/MS analysis. At elevated operating pressures and temperature, the stable C8 phase and rugged column packing technology delivered highly reproducible separations and delivered excellent chromatographic run-to-run results.
منابع مشابه
Comparing HILIC and RPLC of Morphine Using Agilent ZORBAX RRHD Columns with UHPLC/MS
UHPLC/MS analyses of morphine and 3 of its metabolites (normorphine, morphine3-b-D-glucuronide [M3G], and morphine-6-b-D-glucuronide [M6G]) are used to compare mass spectrometer sensitivity with reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). Two Agilent ZORBAX Rapid Resolution High Definition (RRHD) columns are used in this comparison, an Agilent...
متن کاملAnalysis of Potential Genotoxic Arylamine and Aminopyridine Impurities in Active Pharmaceutical Ingredients Agilent 1290 Infinity LC system and Agilent 6460A Triple Quadrupole MS system for method development and fast analysis
This Application Note illustrates the possibilities of the Agilent 1290 Infinity LC system and the Agilent 6460A Triple Quadrupole Mass Spectrometer for quantitative analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs). A generic approach was used to determine arylamine and aminopyridine PGIs in selected APIs. The influence of column length and mobile ph...
متن کاملEnantioselective Separation of Ofloxacin by Ligand Exchange Chromatography
A ligand exchange HPLC method for enantioseparation of ofloxacin enantiomers was developed by a using C8 stationary phase. Chromatographic separation was performed on a Zorbax-300SB-C8 column eluted with the mobile phase consisting of 15 % methanol in water containing 10mM phenylalanin and 5 mM CuSO4 at flow rate of 0.8 mL/min. The method was simple, rapid and suitable for routine analytical st...
متن کاملReversed-Phase HPLC Separation of Water-Soluble Vitamins on Agilent ZORBAX Eclipse Plus Columns Application
A mixture of six B vitamins and vitamin C were separated on the same Agilent ZORBAX Eclipse Plus C-18 stationary phase in three different particle sizes and column dimensions: 5 μm (4.6 × by 150 mm); Rapid Resolution (RR), 3.5 μm (4.6 × 100 mm), and RR High Throughput (RRHT), 1.8-μm (4.6 × 50 mm). A simple phosphate buffermethanol mobile phase gradient was used. The method was designed to suppl...
متن کاملAnalysis of TCM injections using the Agilent 1290 Infinity LC system
An ultra high performance liquid chromatography (UHPLC) method using an Agilent 1290 Infinity LC system with an Agilent 1290 Infinity Diode Array Detector (DAD) was developed for the separation of Shenmai injections. Good separation of complex systems was achieved by connecting two columns: an Agilent ZORBAX Eclipse Plus C18 column (2.1 mm × 100 mm, 1.8 μm) and an Agilent ZORBAX SB C18 (2.1mm ×...