Continuous noninvasive cardiac output in children: is this the next generation of operating room monitors? Initial experience in 402 pediatric patients.

نویسندگان

  • Charles J Coté
  • Jinghu Sui
  • Thomas Anthony Anderson
  • Somaletha T Bhattacharya
  • Erik S Shank
  • Pacifico M Tuason
  • David A August
  • Audrius Zibaitis
  • Paul G Firth
  • Gennadiy Fuzaylov
  • Michael R Leeman
  • Christine L Mai
  • Jesse D Roberts
چکیده

BACKGROUND Electrical Cardiometry(™) (EC) estimates cardiac parameters by measuring changes in thoracic electrical bioimpedance during the cardiac cycle. The ICON(®), using four electrocardiogram electrodes (EKG), estimates the maximum rate of change of impedance to peak aortic blood acceleration (based on the premise that red blood cells change from random orientation during diastole (high impedance) to an aligned state during systole (low impedance)). OBJECTIVE To determine whether continuous cardiac output (CO) data provide additional information to current anesthesia monitors that is useful to practitioners. METHODS After IRB approval and verbal consent, 402 children were enrolled. Data were uploaded to our anesthesia record at one-minute intervals. Ten-second measurements (averaged over the previous 20 heart beats) were downloaded to separate files for later comparison with routine OR monitors. RESULTS Data from 374 were in the final cohort (loss of signal or improper lead placement); 292,012 measurements during 58,049 min of anesthesia were made in these children (1 day to 19 years and 1 to 107 kg). Four events had a ≥25% reduction in cardiac index at least 1 min before a clinically important change in other monitored parameters; 18 events in 14 children confirmed manifestations of other hemodynamic measures; eight events may have represented artifacts because the observed measurements did not seem to fit the clinical parameters of the other monitors; three other events documented decreased stroke index with extreme tachycardia. CONCLUSIONS Electrical cardiometry provides real-time cardiovascular information regarding developing hemodynamic events and successfully tracked the rapid response to interventions in children of all sizes. Intervention decisions must be based on the combined data from all monitors and the clinical situation. Our experience suggests that this type of monitor may be an important addition to real-time hemodynamic monitoring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laparoscopic-Assisted Percutaneous Extraperitoneal Closure for Inguinal Hernia Repair in Children: An Initial Experience

Over the past two decades, laparoscopy has advanced and multiple techniques for inguinal hernia repair have been established. Laparoscopic-assisted percutaneous extraperitoneal closure (LAPEC) for inguinal hernia repair in children, is one of the most simple and reliable methods. The present study aimed to assess the safety and feasibility of the LAPEC of inguinal hernia in children.From Januar...

متن کامل

Operating Room Scheduling Considering Patient Priorities and Operating Room Preferences: A Case Study

Operating rooms have become the most important areas in hospitals because of the scarcity and cost of resources. The present study investigates operating room scheduling and rescheduling considering the priority of surgical patients in a specialized hospital. The ultimate purpose of scheduling is to minimize patient waiting time, surgeon idle time between surgeries, and penalties for deviations...

متن کامل

Noninvasive monitoring cardiac output using partial CO(2) rebreathing.

This article reviews use of partial carbon dioxide rebreathing devices to determine cardiac output and their application for hemodynamic monitoring in the ICU and operating room. The primary focus is on the NICO monitoring device. Compared with conventional cardiac output methods, these techniques are noninvasive, easily automated, and provide real-time and continuous cardiac output monitoring....

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Right Atrium Laceration with Pericardial Tamponade: A Rare Presentation of Blunt Cardiac Trauma

Cardiac laceration from blunt thoracic trauma is not a common presentation. The rate of mortality due to this injury is very high since it is not diagnosed and treated immediately. In this study, we present the case of a 65-year-old man with blunt cardiac trauma, causing right atrial rupture and pericardial tamponade. Successful management of this patient was firstly done with initial pericardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Paediatric anaesthesia

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2015