Dissemination of respiratory secretions during tracheal tube suctioning in an intensive care unit.

نویسندگان

  • K S Ng
  • G Kumarasinghe
  • T J Inglis
چکیده

Most intensive care patients require frequent tracheal toilet, a procedure usually performed by suctioning the tracheal tube. Such procedures often result in the production and dissemination of droplets. We measured the distance visible droplets disseminated during tracheal tube suctioning of patients in an adult surgical intensive care unit. Fifty consecutive suction procedures in 14 patients intubated with a cuffed tracheal tube were investigated. Visible droplets were scattered over a mean distance of 60 +/- 39 cm (range 25 to 168 cm) from the tracheal tube. Blood agar culture plates were placed at three fixed points from the tracheal tube to identify organisms resulting from environmental contamination (control plates). This was repeated during suctioning procedures (study plates) to look into the occurrence of bacteriological cultures that differ from the control plates. Nine of the 14 patients had tracheal tube aspirate cultures done as part of their work-up for sepsis. In more than 30% of the suctioning procedures on these 9 patients, study plates grew bacteria that were similar to those present in their tracheal tube aspirates. In view of these observations, greater care should be taken to avoid contamination of the patient's immediate environment during tracheal tube suctioning and in the design of the intensive care unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracheal secretion management in the mechanically ventilated patient: comparison of standard assessment and an acoustic secretion detector.

BACKGROUND Standard indications for endotracheal suctioning are often based on clinical judgment on the deterioration of the patient's condition, and/or routine suctioning. TBA Care is a secretion detector that analyses airway sounds and indicates the need for suctioning. OBJECTIVE To determine the efficacy of TBA Care in detecting retained secretions, compared to standard indications. METH...

متن کامل

Ventilator-Associated Pneumonia in Patients Admitted to Intensive Care Units, Using Open or Closed Endotracheal Suctioning

BACKGROUND Critically ill patients under mechanical ventilation require frequent suctioning of airway secretion. Closed suction permits suctioning without disconnection from ventilator; so it might decrease hypoxemia and infection rate. OBJECTIVES This study aimed to evaluate the effect of closed tracheal suction system (CTSS) versus open tracheal suction system (OTSS). PATIENTS AND METHODS...

متن کامل

Comparing the Effect of Using Normal Saline and Distilled Water for Tracheal Suctioning on the Incidence of Ventilator-associated Pneumonia and Hemodynamic Indexes in Ventilator-dependent Patients

Background and Aims: VAP prevention is a top priority in the intensive care units. The study was conducted to compare the effect of using normal saline and distilled water for tracheal suctioning on the incidence of ventilator-associated pneumonia and hemodynamic indexes in ventilator-dependent patients. Methods: The present study is a randomized clinical trial that was conducted from 2017 to 2...

متن کامل

Instillation of normal saline before suctioning reduces the incidence of pneumonia in intubated and ventilated adults.

QUESTION Does the instillation of normal saline before suctioning reduce the incidence of ventilator-associated pneumonia in intubated and ventilated adults? DESIGN Randomised, controlled trial with blinded outcome assessment. SETTING The medical/surgical intensive care unit of a tertiary oncology hospital in Brazil. PARTICIPANTS Adults expected to require at least 72 hours of mechanical ...

متن کامل

Endotracheal suctioning in intubated newborns: an integrative literature review

Evidence-based practices search for the best available scientific evidence to support problem solving and decision making. Because of the complexity and amount of information related to health care, the results of methodologically sound scientific papers must be integrated by performing literature reviews. Although endotracheal suctioning is the most frequently performed invasive procedure in i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 1999