Basin-wide analysis of the dynamics of fecal contamination and fecal source identification in Tillamook Bay, Oregon.

نویسندگان

  • Orin C Shanks
  • Christopher Nietch
  • Michael Simonich
  • Melissa Younger
  • Don Reynolds
  • Katharine G Field
چکیده

The objectives of this study were to elucidate spatial and temporal dynamics in source-specific Bacteroidales 16S rRNA genetic marker data across a watershed; to compare these dynamics to fecal indicator counts, general measurements of water quality, and climatic forces; and to identify geographic areas of intense exposure to specific sources of contamination. Samples were collected during a 2-year period in the Tillamook basin in Oregon at 30 sites along five river tributaries and in Tillamook Bay. We performed Bacteroidales PCR assays with general, ruminant-source-specific, and human-source-specific primers to identify fecal sources. We determined the Escherichia coli most probable number, temperature, turbidity, and 5-day precipitation. Climate and water quality data collectively supported a rainfall runoff pattern for microbial source input that mirrored the annual precipitation cycle. Fecal sources were statistically linked more closely to ruminants than to humans; there was a 40% greater probability of detecting a ruminant source marker than a human source marker across the basin. On a sample site basis, the addition of fecal source tracking data provided new information linking elevated fecal indicator bacterial loads to specific point and nonpoint sources of fecal pollution in the basin. Inconsistencies in E. coli and host-specific marker trends suggested that the factors that control the quantity of fecal indicators in the water column are different than the factors that influence the presence of Bacteroidales markers at specific times of the year. This may be important if fecal indicator counts are used as a criterion for source loading potential in receiving waters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of pH, Chlorine Residual and Turbidity on the Microbial Bio Indicators of Drinking Water Network

Abstract Background and objective: Bioindicators of drinking water are always influenced by physical and chemical factors such as turbidity and chlorine.  Considering the assessment of drinking water quality is based on residual chlorine, E.coli, heterotrophic bacteria and turbidity.  We aimed to evaluate the effect of pH, chlorine residual and turbidity on the microbial ...

متن کامل

Assessment of Fecal Contamination in Oklahoma Water Systems through the Use of Sterol Fingerprints

Fecal contamination is a major concern for water quality management, since the fecal materials are associated with pathogens that can cause illness wherever water is used for recreational, drinking and aquaculture purposes. In order to monitor source(s) of fecal contamination in Oklahoma water systems, sterol profiles were previously examined in rural and urban samples collected from the Illino...

متن کامل

Molecular Identification of Giardia intestinalis and Blastocystis hominis Genotypes from Fecal Samples in Khuzestan Province, Iran

Background and purpose: Giardia and Blastocystis are common parasites of humans with a wide range of hosts. The aim of this study was to identify the genotypes of Giardia intestinalis and Blastocystis hominis in individuals attending Bavi health centers in Khuzestan province, Iran. Materials and methods: In this study, 30 positive stool samples of Giardia and Blastocystis were collected from i...

متن کامل

تعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN

Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...

متن کامل

Use of Caffeine and Human Pharmaceutical Compounds to Identify Sewage Contamination

Fecal coliform bacteria are widely used as indicators of sewage contamination in surface water. However, there are some disadvantages in these microbial techniques including time consuming (18-48h) and inability in discriminating between human and animal fecal material sources. Therefore, it is necessary to seek a more specific indicator of human sanitary waste. In this study, the feasibility w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 72 8  شماره 

صفحات  -

تاریخ انتشار 2006