Measurement of flow through perfused bronchial segments: optimization of flow head resistance.

نویسندگان

  • P K McFawn
  • M P Sparrow
  • H W Mitchell
چکیده

Techniques for measuring flow, for example through perfused bronchial segments, frequently use a flow head as the sensing device. The sensitivity of these instruments to changes in airway resistance is dependent on the flow head resistance. This study aims to quantify the effect of flow head resistance on sensitivity and flow, allowing optimization of flow head resistance. A mathematical model of the perfused bronchial segment preparation was constructed and used to explore the effect of flow head resistance on sensitivity. The model's assumptions were experimentally tested using segments of pig bronchus, perfused through the lumen with Krebs solution. The model suggests a complex relationship between flow head resistance and sensitivity that has a distinct maximum when approximately half of the total resistance is present in the flow head. Furthermore, the maximum sensitivity was found to be proportional to the resting flow. Regression between experimentally derived sensitivities and modelled predictions was linear, with a correlation coefficient of 0.93. We have defined the optimum recording conditions for study of flow through isolated bronchial segments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Video-imaging of lumen narrowing; muscle shortening and flow responsiveness in isolated bronchial segments of the pig.

The amount of smooth muscle shortening required to cause narrowing of the bronchial lumen and to significantly alter airflow in an airway has not not been measured. Accordingly, in this study, the lumens of isolated fluid-filled bronchial segments from pigs were directly visualized using a fibreoptic endoscope and video-recording. The extent of lumen narrowing was related to smooth muscle contr...

متن کامل

A method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow

Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...

متن کامل

Effect of hypoxia on pulmonary blood flow-segmental vascular resistance relationship in perfused cat lungs.

To investigate the effect of alveolar hypoxia on the pulmonary blood flow-segmental vascular resistance relationship, we determined the longitudinal distribution of vascular resistance while increasing blood flow during hyperoxia or hypoxia in perfused cat lungs. We measured microvascular pressures by the micropipette servo-null method, partitioned the pulmonary vessels into three segments [i.e...

متن کامل

ECT and LS-SVM Based Void Fraction Measurement of Oil-Gas Two-Phase Flow

A method based on Electrical Capacitance Tomography (ECT) and an improved Least Squares Support Vector Machine (LS-SVM) is proposed for void fraction measurement of oil-gas two-phase flow. In the modeling stage, to solve the two problems in LS-SVM, pruning skills are employed to make LS-SVM sparse and robust; then the Real-Coded Genetic Algorithm is introduced to solve the difficult problem...

متن کامل

Exchange of blood between pulmonary and systemic circulations via bronchopulmonary anastomoses.

• The existence of brouchopulmonary anastomoses has led to the general belief that the blood from the aorta and bronchial arteries can reach the pulmonary vessels and left atrium. There is reasonable evidence to suggest that the reverse can occur. Three observations pertain to the flow of blood from the pulmonary artery to the bronchial veins and right atrium: (a) In 1931 Berry and Daly perfuse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 1995