Optimizing Technology Research of Imaging Quality on X-ray Digital Imaging
نویسندگان
چکیده
It has become an inevitable development that X-ray digital imaging detectors replace film-screen. The imaging quality of X-ray digital detector could not reach the level of film-screen due to its unique characteristics. It is the key that to research the method of improving and optimizing the digital imaging quality. The main factors to impact X-ray digital imaging quality is inherent non-uniformity of detector and random noise of the system. By analyzing imaging characteristics and mechanism of digital detector the non-uniformity correction model is established. The high imaging quality obtained is equal to B level of film-screen for contrast sensitivity in the condition of optimizing physical and penetrating parameters of X-ray digital imaging system with noise suppression technology. The optimization technology validated by experiment is feasibility and universal, can be applied to all types of X-ray digital testing systems.
منابع مشابه
Image quality enhancement in digital panoramic radiograph
One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...
متن کاملMedical Imaging Teacher: A Program to Simulate X-Ray Images of the Body by Considering kVp, mAs, and FFD Values
Introduction: Teaching styles and methods have been constantly changing in the recent years. In the 1980s and 90s, the world was introduced to various developed devices, such as smart boards and early generation smart phones that had an immediate innovative effect on education. These advancements has resulted in a considerable improvement in the current educational techniques. The innovations i...
متن کاملEOS imaging versus current radiography: A health technology as-sessment study
Background: EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imag...
متن کاملمقایسه دوز اشعه دریافتی تیروئید و عدسی چشم در رادیوگرافی معمولی و رادیوویزیوگرافی
This article presents a comparative clinical study of digital imaging, as a new technology, and conventional method for X - Ray absorption in lens and thyroid.Clinical examination was performed on 50 patients with an average of 28 years among the cases who were reffered to the department of rediology, Islamic Azad universiy of IRAN in 1999.Two pocket dosimeters were used to meausre the dose rat...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کامل