Natural Remission of Major Periprosthetic Osteolysis following Total Hip Arthroplasty with Metal-on-Metal Bearings
نویسندگان
چکیده
The natural course of adverse events following the use of metal-on-metal (MoM) bearings in total hip arthroplasty (THA) is not well known. In this article, we report the case of a patient with asymptomatic major acetabular osteolysis following MoM THA that diminished gradually without any surgical intervention. A 58-year-old male underwent one-stage bilateral MoM THA for bilateral osteoarthritis. Four years after THA, major acetabular osteolysis developed in his right hip without any local or systemic symptoms. The patient underwent a careful radiographic and clinical observation without any surgical intervention because he did not want to undergo revision surgery. The lesion gradually diminished after 7 years, and most of the osteolytic area was replaced by newly formed bone at 10 years. He continues to be followed with no evidence of cup loosening or migration. Our observation suggests that a periprosthetic osteolytic change related to the use of MoM bearings has the potential for natural remission.
منابع مشابه
Early osteolysis following second-generation metal-on-metal hip replacement.
BACKGROUND Total hip arthroplasty with use of metal-on-metal bearings has been reintroduced as an alternative to the use of metal-on-polyethylene bearings because of theoretical advantages such as reduced wear and a lower prevalence of osteolysis. However, we observed early osteolysis in a cohort of patients who had been managed with second-generation metal-on-metal hip replacements and investi...
متن کاملAntibiotic-impregnated Cement Plate for the Treatment of Infected Periprosthetic Femoral Fracture after Cementless Total Hip Arthroplasty - A Case Report -
Copyright c 2012 by Korean Hip Society 245 Periprosthetic femoral fracture is a problematic complication of total hip arthroplasty (THA). Although treatment protocols for periprosthetic femoral fracture have been reported, treatment protocols for periprosthetic fracture with accompanying infection have rarely been published. When these two complications occur together, it becomes more difficult...
متن کاملAlumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...
متن کاملAdverse soft-tissue reactions around non-metal-on-metal total hip arthroplasty - a systematic review of the literature.
UNLABELLED Adverse local soft-tissue reactions have been associated with severe osteolysis and implant failure in metal-on-metal total hip arthroplasty (THA). Such a causal relationship has not often been associated with non metal-on-metal bearing surfaces. The purpose of this study was to assess the literature for cases of adverse soft-tissue reactions in non-metal-on-metal bearings in order t...
متن کاملEleven-year follow-up of second-generation metal-on-metal total hip arthroplasty.
PURPOSE To investigate the cause of failure in matte-surface cemented stems in second-generation metal-on- metal total hip arthroplasty (THA). METHODS Records of 26 men and 11 women (39 hips) aged 29 to 72 years who underwent primary cementless THAs by a single surgeon using second-generation metal-on-metal prostheses and were followed up for a mean of 122 (range, 120-141) months were reviewe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017