State-Space Transient Analysis of Single-Phase Transmission Lines with Corona

نویسنده

  • Mehmet Salih Mamis
چکیده

State-space techniques are used for the computation of the surge response of a transmission line with corona. The transmission line is treated as the series connection of short line sections, and the effect of corona is represented in each section by a nonlinear (voltage dependent) capacitor-conductance branch. Surge response of the transmission line is obtained for various corona models by taking into account the corona loss and the dynamic variation of the corona parameters. Computed results are compared with measured results available in the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA

In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...

متن کامل

Spice Compatible Model for Multiple Coupled Nonuniform Transmission Lines Application in Transient Analysis of VLSI Circuits

An SPICE compatible model for multiple coupled nonuniform lossless transmission lines (TL's) is presented. The method of the modeling is based on the steplines approximation of the nonuniform TLs and quasi-TEM assumptions. Using steplines approximation the system of coupled nonuniform TLs is subdivided into arbitrary large number of coupled uniform lines (steplines) with different characteristi...

متن کامل

Attenuation and deformation characteristics of lightning impulse corona traveling along bundled transmission lines

Comprehensive study of the impulse corona characteristics is helpful to understand the transient process and guarantee a suitable insulation design of power transmission systems. In this paper, first the attenuation and deformation characteristics of lightning overvoltage traveling along a 500 kV experimental transmission line are tested. Then the lightning impulse corona characteristics on dif...

متن کامل

Single Server Bulk Queue with Service Interruption, Two Phase Repairs and State Dependent Rates

This paper reports a study on a single server queue with bulk arrival and bulk service patterns wherein the incoming traffic depends on the state of the server which may be in operating or breakdown state. The repair of the breakdown server is performed in two phases. The operating duration of server, repair duration of both phases of repairing as well as job's inter-arrival times and service t...

متن کامل

Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes

In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003