Sample introduction valve used in ICP-AES for faster analysis

نویسنده

  • Helge Stray
چکیده

A twin six-port valve with two sample loops was installed between the autosampler and the nebuliser of a simultaneous inductively coupled plasma-atomic emission spectrometer. The valve was mounted close to the nebuliser inlet so that the time required for the sample to enter from the loop to the nebulizer was less than 0.5 s. The content of one loop was introduced to the nebulizer using a peristalic pump, whilst a second loop was filed with the next sample using a second peristaltic pump. The washout time was in this manner reduced by 20 s per analysis and the hourly sampling rate was increased from 90 to 180 in the measurements described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of total arsenic and arsenic species stability in alga samples and their aqueous extracts.

In order to achieve reliable information on speciation analysis, it is necessary to assess previously the species stability in the sample to analyse. Furthermore, in those cases where the sample treatment for species extraction is time-consuming, an assessment of the species integrity in the extracts is of paramount importance. Thus, the present paper reports total arsenic and arsenic species s...

متن کامل

Mapping Copper and Lead Concentrations at Abandoned Mine Areas Using Element Analysis Data from ICP–AES and Portable XRF Instruments: A Comparative Study

Understanding spatial variation of potentially toxic trace elements (PTEs) in soil is necessary to identify the proper measures for preventing soil contamination at both operating and abandoned mining areas. Many studies have been conducted worldwide to explore the spatial variation of PTEs and to create soil contamination maps using geostatistical methods. However, they generally depend only o...

متن کامل

The Analysis of Ecstasy Tablets by Icp/ms and Icp/aes

In this study, tablets coming from different police seizures (in Switzerland) were analysed by ICP/MS and ICP/AES. Two methods of preparation were carried out in order to compare the influence of sample preparation. 25 elements were screened by ICP/AES whereas most of the periodic table could be screened by ICP/MS. Approximative detection limits were determined for most of the elements showing,...

متن کامل

Determination of soluble toxic arsenic species in alga samples by microwave-assisted extraction and high performance liquid chromatography-hydride generation-inductively coupled plasma-atomic emission spectrometry

A microwave-based procedure for arsenic species extraction in alga samples (Sargassum fulvellum, Chlorella vulgaris, Hizikia fusiformis and Laminaria digitata) is described. Extraction time and temperature were tested in order to evaluate the extraction efficiency of the process. Arsenic compounds were extracted in 8 ml of deionised water at 90 °C for 5 min. The process was repeated three times...

متن کامل

Analysis of Acid Rock Drainage (ARD) with Micro Plasma Atomic Emission Spectroscopy (MP AES) – Comparison with ICP-MS

Analysis of dissolved metals in acid rock drainage (ARD) with an Agilent 4100 MP AES instrument that combines a nitrogen micro plasma with atomic emission detection (MP AES) was compared with an ICP-MS. Sample preparation consisted only of filtration, acidification (HNO3 1%) and addition of internal standard elements after appropriate dilution. In these complex matrices the systems gave identic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1989