Does the Location of Bruch's Membrane Opening Change Over Time? Longitudinal Analysis Using San Diego Automated Layer Segmentation Algorithm (SALSA)
نویسندگان
چکیده
PURPOSE We determined if the Bruch's membrane opening (BMO) location changes over time in healthy eyes and eyes with progressing glaucoma, and validated an automated segmentation algorithm for identifying the BMO in Cirrus high-definition coherence tomography (HD-OCT) images. METHODS We followed 95 eyes (35 progressing glaucoma and 60 healthy) for an average of 3.7 ± 1.1 years. A stable group of 50 eyes had repeated tests over a short period. In each B-scan of the stable group, the BMO points were delineated manually and automatically to assess the reproducibility of both segmentation methods. Moreover, the BMO location variation over time was assessed longitudinally on the aligned images in 3D space point by point in x, y, and z directions. RESULTS Mean visual field mean deviation at baseline of the progressing glaucoma group was -7.7 dB. Mixed-effects models revealed small nonsignificant changes in BMO location over time for all directions in healthy eyes (the smallest P value was 0.39) and in the progressing glaucoma eyes (the smallest P value was 0.30). In the stable group, the overall intervisit-intraclass correlation coefficient (ICC) and coefficient of variation (CV) were 98.4% and 2.1%, respectively, for the manual segmentation and 98.1% and 1.9%, respectively, for the automated algorithm. CONCLUSIONS Bruch's membrane opening location was stable in normal and progressing glaucoma eyes with follow-up between 3 and 4 years indicating that it can be used as reference point in monitoring glaucoma progression. The BMO location estimation with Cirrus HD-OCT using manual and automated segmentation showed excellent reproducibility.
منابع مشابه
An Automated MR Image Segmentation System Using Multi-layer Perceptron Neural Network
Background: Brain tissue segmentation for delineation of 3D anatomical structures from magnetic resonance (MR) images can be used for neuro-degenerative disorders, characterizing morphological differences between subjects based on volumetric analysis of gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF), but only if the obtained segmentation results are correct. Due to image arti...
متن کاملStructural Change Can Be Detected in Advanced-Glaucoma Eyes
PURPOSE To compare spectral-domain optical coherence tomography (SD-OCT) standard structural measures and a new three-dimensional (3D) volume optic nerve head (ONH) change detection method for detecting change over time in severely advanced-glaucoma (open-angle glaucoma [OAG]) patients. METHODS Thirty-five eyes of 35 patients with very advanced glaucoma (defined as a visual field mean deviati...
متن کاملDigital Direct-to-Consumer Advertising: A Perfect Storm of Rapid Evolution and Stagnant Regulation; Comment on “Trouble Spots in Online Direct-to-Consumer Prescription Drug Promotion: A Content Analysis of FDA Warning Letters”
The adoption and use of digital forms of direct-to-consumer advertising (also known as “eDTCA”) is on the rise. At the same time, the universe of eDTCA is expanding, as technology on Internet-based platforms continues to evolve, from static websites, to social media, and nearly ubiquitous use of mobile devices. However, little is known about how this unique form of pharmaceutical marketing impa...
متن کاملDoes Type of Pain Predict Pain Severity Changes in Individuals With Multiple Sclerosis? A Longitudinal Analysis Using Generalized Estimating Equations
Background & Objective: Pain is a common symptom among people with MS. In the majority of MS patients, pain is chronic in nature, but it can change over time. The objective of this study was to determine if pain type can predict pain severity changes in individuals with MS over time. Materials & Methods: The research method was a longitudinal design that evaluated pain type and severity at...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کامل