Is there a link between nickel allergy and coronary stent restenosis?
نویسندگان
چکیده
Although many patients with coronary artery disease are being treated by coronary stents, in-stent restenosis is the major limitation of percutaneous coronary stenting procedures. Most stents are made of stainless steel, and that, allergic reactions to nickel ions released from coronary stainless-steel stents may be one of the triggering mechanisms for in-stent restenosis. We aimed to evaluate the relationship between in-stent restenosis and nickel allergy in a prospective study. For this purpose, we applied epicutaneous patch test for nickel in 43 patients who had undergone elective intracoronary stent placement for stable angina pectoris in the day following stent placement and evaluated the presence of nickel allergy. Control angiography was performed at 6 months to determine in-stent restenosis. Three (6.9%) patients had allergic reaction to nickel and 16 (37%) patients had developed in-stent restenosis. One of the 3 patients with nickel allergy had diffuse in-stent restenosis and the others not. The present study therefore does not support the proposed relationship between nickel allergy and development of in-stent restenosis in patients having stainless steel stents. Large scale studies are needed to reach a final conclusion.
منابع مشابه
Does nickel allergy play a role in the development of in-stent restenosis?
OBJECTIVES It was suggested that coronary in-stent restenosis might be triggered by allergy to nickel and molybdenum ions released from stainless-steel stents. We sought to explore any possible relationship between nickel allergy and in-stent restenosis. MATERIALS AND METHODS 50 patients were studied, who underwent elective follow-up coronary angiography for recurrent symptoms after prior cor...
متن کاملRelation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents
BACKGROUND In-stent restenosis (ISR) is the major limitation of percutaneous coronary stenting procedure. The elements like nickel, chromate and molybdenum are known to cause contact allergy. Hypersensitivity reaction, against these metal ions, may be one of the reasons of ISR. Cobalt chromium coronary stents, which are increasingly being used in percutaneous coronary interventions, have more n...
متن کاملSirolimus-eluting stents suppress neointimal formation irrespective of metallic allergy.
BACKGROUND Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated. METHODS AND RESULTS The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting sten...
متن کاملGranulation tissue with eosinophil infiltration in the restenotic lesion after coronary stent implantation.
Although stents reduce the rate of vessel restenosis, in-stent restenosis is a recognized clinical problem and it appears that patients positive for allergic patch-test reactions to the stent components nickel and molybdenum have increased rates of it. A patient with angina pectoris had repeated episodes of restenosis after stent implantation and histological examination demonstrated granulatio...
متن کاملAssociation of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent
In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Tohoku journal of experimental medicine
دوره 206 3 شماره
صفحات -
تاریخ انتشار 2005