Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

نویسندگان

  • Hon-Tym Wong
  • Jocelyn L L Chua
  • Lisandro M Sakata
  • Melissa H Y Wong
  • Han T Aung
  • Tin Aung
چکیده

OBJECTIVE To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. METHODS A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. RESULTS A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P < .001; gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P < .001; McNemar test). Of the 51 eyes with a closed ACA on gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. CONCLUSION Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COVER STORY: ANGLE-CLOSURE GL AUCOM A Beyond relative pupillary block—identifying alternative mechanisms

D iagnostic tools for the detection of primary angle closure include old stalwarts such as gonioscopy and slit-lamp estimation of limbal anterior chamber depth1,2 as well as new technologies that yield high-resolution, cross-sectional images of the angle. In addition to their diagnostic potential, anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) have pro...

متن کامل

Anterior Segment Optical Coherence Tomography for the Quantitative Evaluation of the Anterior Segment Following Boston Keratoprosthesis

OBJECTIVE To quantitatively evaluate the anterior segment using anterior segment optical coherence tomography (AS-OCT) following Boston keratoprosthesis type 1. METHODS A retrospective study consisted of AS-OCT imaging at a single time point postoperatively in 52 eyes. Main outcomes measures include anatomical and functional anterior chamber depth (ACD), angle (ACA) and peripheral and proxima...

متن کامل

Anterior Segment Optical Coherence Tomography Changes to the Anterior Chamber Angle in the Short-term following Laser Peripheral Iridoplasty

PURPOSE To evaluate, by anterior segment optical coherence tomography (AS-OCT), the changes in the anterior chamber angle during the short-term postoperative period after diode laser peripheral iridoplasty (LPI). METHODS Retrospective, observational study of consecutive primary angle closure suspect, primary angle closure, or primary angle closure glaucoma patients who underwent LPI. These pa...

متن کامل

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

Peripheral iris thickness and association with iridotrabecular contact after laser peripheral iridotomy in patients with primary angle-closure and primary angle-closure glaucoma

PURPOSE To investigate the relation between the quantitative iris parameters and iridotrabecular contact (ITC) in patients with primary angle-closure (PAC) and PAC glaucoma (PACG). MATERIALS AND METHODS PAC and PACG with laser peripheral iridotomy were recruited prospectively. Anterior-segment optical coherence tomography (ASOCT) was performed under light and dark conditions, and scans were t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 127 5  شماره 

صفحات  -

تاریخ انتشار 2009