OBJECTIVE The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers. SUBJECTS AND METHODS RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95 degrees C. Helical unenhanced CT and corresponding axial sonography were performed before ablation, at 2 min, 8 min, and immediately after ablation. Contrast-enhanced CT was performed after ablation. CT scans and sonograms were evaluated by blinded observers for conspicuity of the RF lesion, edge detection (visibility of liver-lesion interface), and artifacts. Hounsfield units were recorded at every time interval, and radiologic-pathologic correlation for lesion size and configuration was performed. RESULTS Mean size of RF lesions was 3. 03 +/- 0.9 cm. On CT, RF lesions had consistently lower attenuation values than surrounding liver (22.2 H lower than liver at 8 min, p < 0.0001). Echogenicity was variable with sonography (hypoechoic = 59%, hyperechoic = 25%, isoechoic = 16%). Unenhanced CT significantly improved conspicuity, edge detection of RF lesions, and decreased artifacts compared with sonography (p < 0.05). Contrast-enhanced CT improved RF lesion detection, border discrimination, and artifacts compared with sonography (p < 0.05). Unenhanced CT had the best correlation to pathologic size (r = 0.74), followed by contrast-enhanced CT (r = 0.72) and sonography (r = 0.56). Contrast-enhanced CT best correlated with lesion shape, but slightly overestimated size because of areas of ischemia peripheral to the RF lesion. CONCLUSION In this animal model, unenhanced CT was an effective way to monitor RF ablation compared with sonography because of increased lesion discrimination, reproducible decreased attenuation during ablation, and improved correlation to pathologic size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

Thermographic real-time-monitoring of surgical radiofrequency and microwave ablation in a perfused porcine liver model

Radiofrequency ablation (RFA) and microwave ablation (MWA) are currently the dominant modalities to treat unresectable liver tumors. Monitoring the ablation process with b-mode-sonography is often hampered by artefacts. Furthermore, vessels may cause cooling in the adjacent tumor target (heat-sink-effect) with risk of local recurrence. The present study evaluated infrared-thermography to monito...

متن کامل

Radiofrequency Ablation with the Real-Time Virtual Sonography System for Treating Hepatocellular Carcinoma Difficult to Detect by Ultrasonography

Radiofrequency ablation has been applied to treat hepatocellular carcinoma, with favorable therapeutic outcomes. Nevertheless, practitioners have approached radiofrequency ablation with some reluctance due to the difficulty of identifying isoechoic tumors and recurrent tumors. The aim of the present study is to investigate the efficacy of Real-time Virtual Sonography to treat hepatocellular car...

متن کامل

Fiber-optic chirped FBG for distributed thermal monitoring of ex-vivo radiofrequency ablation of liver.

A linearly chirped fiber Bragg grating (LCFBG) has been used as a temperature sensor for online monitoring of radiofrequency thermal ablation (RFTA). The LCFBG acts as a distributed sensor, with spatial resolution of 75 μm. A white-light setup that records the LCFBG spectrum estimates the temperature profile in real time. Three RFTA experiments have been performed ex-vivo on porcine liver measu...

متن کامل

Real-time Semi-automatic Segmentation of Hepatic Radiofrequency Ablated Lesions in an In Vivo Porcine Model Using Sonoelastography

Radiofrequency ablation (RFA) is a minimally invasive thermal therapy that is under investigation as an alternative to surgery for treating liver tumors. Currently, there is a need to monitor the process of lesion creation to guarantee complete treatment of the diseased tissue. In a previous study, sonoelastography was used to detect and measure RFA lesions during exposed liver experiments in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 175 3  شماره 

صفحات  -

تاریخ انتشار 2000