Sampling Rate of Heart Rate Variability Impacts the Ability to Detect Acidemia in Ovine Fetuses Near-Term

نویسندگان

  • L. Daniel Durosier
  • Geoffrey Green
  • Izmail Batkin
  • Andrew J. Seely
  • Michael G. Ross
  • Bryan S. Richardson
  • Martin G. Frasch
چکیده

BACKGROUND To evaluate the impact of sampling rate on the predictive capability of continuous fetal heart rate (FHR) variability (fHRV) monitoring for detecting fetal acidemia during labor, we tested the performance of the root mean square of successive differences (RMSSD) in R-R intervals from the ECG when acquired with the sampling rate of 4 Hz currently available in FHR monitors, in comparison to the gold standard of 1000 Hz. METHODS Near-term ovine fetuses (N = 9) were chronically prepared with precordial electrodes for recording ECG, vascular catheters for blood sampling, and an umbilical cord occluder. For 1 min every 2.5 min, animals underwent mild partial umbilical cord occlusions (UCO) × 1 h, moderate partial UCO × 1 h, then complete UCO × 2 h, or until arterial pH reached <7.00. Arterial blood samples were drawn at baseline and every 20 min during the UCO series. RMSSD was calculated continuously in 5 min windows using an automated, standardized system (CIMVA.com). RESULTS are presented as mean ± SEM with significance assumed for p < 0.05. RESULTS Repetitive UCO resulted in pH decreasing from 7.35 ± 0.01 to 7.00 ± 0.03. In all nine animals, RMSSD increased from 16.7 ± 1.0 ms at baseline to 44.4 ± 2.3 ms, 70 ± 15 min prior to reaching the pH nadir when sampled at 1000 Hz. When sampled at 4 Hz, RMSSD at baseline measured 36.1 ± 6.0 ms and showed no significant increase during the UCO series until the pH nadir was reached. Consequently, early detection of severe hypoxic-acidemia would have been missed in all fetuses. CONCLUSION RMSSD as a measure of fHRV when calculated from FHR sampled at 1000 Hz allowed for the early detection of worsening hypoxic-acidemia in each fetus. However, when calculated at the low sampling rate of 4 Hz used clinically, RMSSD remained unchanged until terminally when the nadir pH was reached. For early detection of fetal acidemia during labor, more sensitive means of acquiring FHR are therefore recommended than currently deployed, e.g., trans-abdominal fetal ECG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acceleration and Deceleration Capacity of Fetal Heart Rate in an In-Vivo Sheep Model

BACKGROUND Fetal heart rate (FHR) variability is an indirect index of fetal autonomic nervous system (ANS) integrity. FHR variability analysis in labor fails to detect early hypoxia and acidemia. Phase-rectified signal averaging (PRSA) is a new method of complex biological signals analysis that is more resistant to non-stationarities, signal loss and artifacts. It quantifies the average cardiac...

متن کامل

مقایسه نتایج Non-stress test اواخر سه ماهه دوم حاملگی در نوزادان با وزن متناسب و نوزادان کوچک نسبت به سن حاملگی در بیمارستان آرش در سال 81-1380

Background: The purpose of this study was to compare electronic fetal heart rate monitoring (EFM) characteristics between Appropriate for Gestational Age (AGA ) and Small for Gestational Age (SGA) fetuses and to determine whether SGA fetuses have specific abnormalities. Materials and Methods: Among children born from Apr 2002 to Mar 2003 in Arash hospital, we identified 300 singleton infants b...

متن کامل

تغییرپذیری ضربان قلب Heart rate variability))

Abstract Many studies have been conducted on heart rate variability. Variability in the heart signal of two sequential beats is called heart rate variability (HRV). Short- and long- term variability reflects autonomic nervous system function, so that increased or decreased heart rate variability (HRV) is an indicator of human health. So, the analysis of these changes can predict sudden death...

متن کامل

تغییرپذیری ضربان قلب Heart rate variability))

Abstract Many studies have been conducted on heart rate variability. Variability in the heart signal of two sequential beats is called heart rate variability (HRV). Short- and long- term variability reflects autonomic nervous system function, so that increased or decreased heart rate variability (HRV) is an indicator of human health. So, the analysis of these changes can predict sudden death...

متن کامل

Developmental aspects of the renal response to hypoxemia in the lamb fetus.

The effects of fetal hypoxemia on renal hemodynamics and renal function were studied in two groups of chronically catheterized young (< 120 days of gestation) and near-term lamb fetuses (> 130 days). Fetal hypoxemia produced, in both groups, a significantly decrease in renal blood flow (RBF) and a significant increase in the filtration fraction. However, the glomerular filtration rate (GFR) did...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014