Ultrasonic Behaviour of Binary Mixtures Containing Stearates and Acetone
نویسندگان
چکیده
The ultrasonic velocity measurements along with density and viscosity in the binary mixtures of zinc stearate acetone and calcium stearate acetone at 303 K are studied. It is used to evaluate the different thermo acoustical parameters along with the excess properties. The experimentally determined velocities have been compared with theoretically estimated values obtained using different empirical theories and relations. The results are utilized to compare the relative merits of these theories and relations in terms of percentage of variation.
منابع مشابه
Correlations and Predictions of THF + 2-Alkanol Binary Mixtures Behaviour by PC-SAFT Model and Friction Theory
In this article the behavior of tetrahydrofuran (THF) + 2-alkanol namely 2-propanol, 2-butanol, 2-pentanol, 2-hexanol and 2-heptanol binary mixtures through the density and viscosity measurements have been studied as a function of composition and within the temperature range of 293.15–313.15 K. The excess molar volume, isobaric thermal expansivity, partial molar volumes, and viscosity deviation...
متن کاملStudy of Molecular Interactions in Stearates and Triethylene Glycol through Ultrasonic Measurements
Speed of sound have been measured as a function of composition for binary mixtures of stearates (zinc stearate and calcium stearate) and triethylene glycol were studied along with density and viscosity values, a comprehensive understanding of the molecular interactions in the binary mixture is thus only possible from the measurements of various physico – chemical properties and treating the exc...
متن کاملExperimental Investigations on the Thermal Performance of a Vertical Closed Loop Pulsating Heat Pipe Using Binary Mixture of Fluids
This paper presents the experimental investigations conducted on a vertical closed loop pulsating heat pipe (VCLPHP) to evaluate the thermal performance. The values of thermal resistance and heat transfer coefficient obtained in the experimentation is used as evaluation parameters. The VCLPHP used has capillary tubes having an inner diameter of 2mm and outside diameter 3mm and bent into 5 turns...
متن کاملUltrasonic Velocity, Density and Viscosity of Binary Liquid Mixtures of Acetone with Toluene, Chlorobenzene and Nitrobenzene
We report the measurements of the speed of sound in the binary liquid mixtures of acetone with toluene, chlorobenzene and nitrobenzene measured at 303 K. The studies on ultrasonic velocity, density and viscosity in binary liquid mixtures have been used to evaluate the different thermo acoustical parameters along with the excess properties. It was found that in all the cases, the experimental da...