Percutaneous implantation of a 26 mm Edwards SAPIEN-XT aortic valve prosthesis in a degenerated 30 mm mitral annuloplasty ring.
نویسندگان
چکیده
della Carità, Novara: G. De Luca, E. Franchi, M. Leverone, A. Rognoni. Clinical events committee: Chairman: Prof. Sandra Brunelleschi PhD. Istituite of Clinical Pharmacology, School of Medicine of the Università del Piemonte Orientale, Novara. Mauro Feola MD, Division of Cardiology, Ospedale S. Trinità, Fossano. Giuliana Menegatti MD, Division of Cardiology, Ospedale Civile Maggiore di Verona. Patrizia Noussan, Ospedale San Giovanni, Torino. Coordinating center: Department of Biomedical Sciences and Surgery, University of Verona. Biostatistics group: Luisa Zanolla MD, Division of Cardiology, University of Verona and Prof. Corrado Magnani PhD, Chairman of the Department of Biostatistics, School of Medicine of the Università del Piemonte Orientale, Novara. Trial registration numbers: In the US: NCT 00369356, in the EU: EUDRACT 2006-000770-75.
منابع مشابه
Transfemoral tricuspid valve-in-ring implantation using the edwards Sapien XT valve: one-year follow-up.
after multidisciplinary evaluation, 3 high-risk patients underwent transfemoral tricuspid valve-in-ring implantation (TVIRI) for refractory congestive heart failure because of deterioration of their tricuspid surgery, using Sapien XT valves (Edwards Lifesciences Inc, Irvine, CA). Patient 1: 44-year-old man, drug abuse, 4 episodes of tricus-pid endocarditis, 2 previous cardiac surgeries for mitr...
متن کاملFailed valve-in-valve transcatheter mitral valve implantation.
A 73-year old man underwent trans-septal anterograde implantation of a 26-mm Sapien-XT valve (Edwards Lifesciences, CA, USA) to treat a degenerated 27-mm Carpentier-Edwards bioprosthesis. During the follow-up, the patient experienced severe haemolysis with moderate-to-severe inter-valvular leak, and fluoroscopy revealed possible incomplete apposition of the Sapien-XT (Fig. 1). Reoperation was p...
متن کاملFirst-in-man implantation of a trans-catheter aortic valve in a mitral annuloplasty ring: novel treatment modality for failed mitral valve repair.
The trans-catheter valve-in-valve concept has become a feasible therapeutic option for patients with failing degenerated bioprosthesis, who are deemed inoperable. However, little is known about the feasibility of this technique in failed valve annuloplasty. We report the first-in-man implantation of a trans-catheter aortic valve within a mitral annuloplasty ring. Through a trans-apical trans-ca...
متن کاملOff-pump transapical mitral valve-in-ring implantation.
OBJECTIVES The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass usin...
متن کاملCase report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure
A 81-year woman was admitted to our institution due to worsening chronic heart failure. The patient presented herself with severe aortic valve stenosis and mitral valve insufficiency. Due to estimated high operative risk a TAVI approach was chosen. Following the fist TAVI implantation (Sapien XT 26 mm) a big paravalvular leakage was diagnosed. Hence, in order to close the paravalular leakage, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 34 23 شماره
صفحات -
تاریخ انتشار 2013