Rapid ion chromatography of L-ascorbic acid, nitrite, sulfite, oxalate, iodide and thiosulfate by isocratic elution utilizing a postcolumn reaction with cerium(IV) and fluorescence detection.
نویسندگان
چکیده
Rapid separation and determination of mixtures of L-ascorbic acid, nitrite, sulfite, oxalate, iodide and thiosulfate by conventional ion chromatography is often difficult due to incomplete separation of L-ascorbic acid and nitrite from the water peak when using eluents giving short elution times for iodide and thiosulfate. Separation of the six species within about 15 min has been achieved by isocratic elution using a resin-based ion-exchange column with a carbonate eluent containing a trace amount of 1,3,5-benzenetricarboxylic acid (BTA) and fluorescence measurement of cerium(III) formed via postcolumn reactions of the separated sample species with cerium(IV). Calibration plots of peak height versus concentration were linear up to 10.0 microM (1.76 ppm) for L-ascorbic acid, 8.0 microM (0.37 ppm) for nitrite, 8.0 microM (0.70 ppm) for oxalate, 80.0 microM (10.2 ppm) for iodide and 25.0 microM (2.80 ppm) for thiosulfate, whilst the sulfite calibration was linear up to 25.0 microM (2.00 ppm) when peak area was plotted against concentration. Detection limits (defined as S/N = 3) were 18 ppb for L-ascorbic acid, 4 ppb for nitrite, 16 ppb for sulfite, 7 ppb for oxalate, 72 ppb for iodide and 37 ppb for thiosulfate. The proposed method was applied successfully to the determination of L-ascorbic acid, nitrite, sulfite, oxalate, iodide or thiosulfate in water samples.
منابع مشابه
Developed Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملKinetic-Spectrophotometric Determination of Track Amounts of Nitrite Ion Based on Its Reduction Reaction with Thionine in Acidic Media
A simple, sensitive and rapid method for determination of trace amounts of nitrite ion in real samples is reported. The reaction is initiated by adding known volumes of a nitrite ion solution of identified concentration to acidic solutions of thionine which causes decolorizaiton of reagent with time. The absorbance changes is then monitored spectrophotometrically at l...
متن کاملA simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملKINETIC-SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF NITRITE BY THE REACTION OF METHYL ORANGE FORMATION
The composite diazotization coupling reaction of sulfanilic acid and N, Ndimethylaniline was used for the precise, accurate, and rapid determination of trace amounts of nitrite ion (0.02-3 µg/ml). The reaction was monitored spectrophotometrically by measuring the absorbance of the produced methyl orange at 510 nm by a fixed the method of 5.0 minutes. The relative standard deviation for the...
متن کاملDevelopment and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes
Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 956 1-2 شماره
صفحات -
تاریخ انتشار 2002