Plasma glucose measurement with the Yellow Springs Glucose Analyzer.

نویسندگان

  • K S Chua
  • I K Tan
چکیده

The Yellow Springs Glucose Analyzer, a device for the quantitative measurement of glucose concentrations, involves the use of immobilized glucose oxidase, incorporated on a membrane covering a hydrogen peroxide sensor. Operation of the instrument is simple. After an initial calibration, 25 microliter of plasma is injected into a reaction chamber. At 45 s a digital result for glucose is displayed. The within-batch coefficient of variation for the method is 1.2% or less for glucose concentrations of 0.94 to 3.98 g/liter. The between-batch coefficient of variation is 5.8% or less for glucose concentrations of 0.29 to 2.91 g/liter. Concentration and readout are linearly related to at least 4.6 g/liter. Analytical recoveries ranged from 100 to 102%. Carry-over was negligible. Values for glucose concentration obtained with the instrument compared well (r = 0.997) with those obtained with the Beckman Glucose Analyzer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System

INTRODUCTION The purpose of the study was to evaluate the performance and usability of the FreeStyle(®) Libre™ Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. MATERIALS AND METHODS Seventy-two study participants with type 1 or type 2 diabetes were enrolled by four U.S. clinical sites. A sensor ...

متن کامل

Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial.

BACKGROUND This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. METHODS Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject wa...

متن کامل

Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640.

BACKGROUND Diabetes mellitus is an important diagnosis. New criteria have been defined for impaired glucose metabolism and, accordingly, there is a need for precise and accurate glucose analysis for the correct classification of patients. However, neither the World Health Organisation nor the National Service Framework for Diabetes in England and Wales deal with the associated analytical issues...

متن کامل

Influence of Iron Deficiency Anemia on Hemoglobin A1C Levels in Diabetic Individuals with Controlled Plasma Glucose Level

Introduction: Hemoglobin A1C (HbA1c) reflects patient’s glycemic status over the previous 3 months. Previous studies have reported that iron deficiency may elevate A1C concentrations, independent of glycemia. This study is aimed to analyze the effect of iron deficiency anemia on HbA1c levels in diabetic population having plasma glucose levels in control. Methods: Totally, 120 diabetic, iron-def...

متن کامل

Accuracy of the SEVEN continuous glucose monitoring system: comparison with frequently sampled venous glucose measurements.

BACKGROUND The purpose of this study was to compare the accuracy of measurements obtained from the DexCom SEVEN system with Yellow Springs Instrument (YSI) laboratory measurements of venous blood glucose. METHODS Seventy-two subjects with insulin-requiring diabetes, aged 18-71, were enrolled in a multicenter, prospective single-arm study. All participants wore the SEVEN continuous glucose mon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1978