Control of a wrist joint motion simulator: A phantom study
نویسندگان
چکیده
The presence of muscle redundancy and co-activation of agonist-antagonist pairs in vivo makes the optimization of the load distribution between muscles in physiologic joint simulators vital. This optimization is usually achieved by employing different control strategies based on position and/or force feedback. A muscle activated physiologic wrist simulator was developed to test and iteratively refine such control strategies on a functional replica of a human arm. Motions of the wrist were recreated by applying tensile loads using electromechanical actuators. Load cells were used to monitor the force applied by each muscle and an optical motion capture system was used to track joint angles of the wrist in real-time. Four control strategies were evaluated based on their kinematic error, repeatability and ability to vary co-contraction. With kinematic errors of less than 1.5°, the ability to vary co-contraction, and without the need for predefined antagonistic forces or muscle force ratios, novel control strategies - hybrid control and cascade control - were preferred over standard control strategies - position control and force control. Muscle forces obtained from hybrid and cascade control corresponded well with in vivo EMG data and muscle force data from other wrist simulators in the literature. The decoupling of the wrist axes combined with the robustness of the control strategies resulted in complex motions, like dart thrower׳s motion and circumduction, being accurate and repeatable. Thus, two novel strategies with repeatable kinematics and physiologically relevant muscle forces are introduced for the control of joint simulators.
منابع مشابه
The effects of wrist motion and hand orientation on muscle forces: A physiologic wrist simulator study
Although the orientations of the hand and forearm vary for different wrist rehabilitation protocols, their effect on muscle forces has not been quantified. Physiologic simulators enable a biomechanical evaluation of the joint by recreating functional motions in cadaveric specimens. Control strategies used to actuate joints in physiologic simulators usually employ position or force feedback alon...
متن کاملInter-Individual Difference in the Effect of Mirror Reflection-Induced Visual Feedback on Phantom Limb Awareness in Forearm Amputees
OBJECTIVE To test whether the phantom limb awareness could be altered by observing mirror reflection-induced visual feedback (MVF) in unilateral forearm amputees. METHODS Ten unilateral forearm amputees were asked to perform bilateral (intact and phantom) synchronous wrist motions with and without MVF. During wrist motion, electromyographic activities in the extensor digitorum longus (EDL) an...
متن کاملGenerating the Visual Biofeedback Signals Applicable to Reduction of Wrist Spasticity: A Pilot Study on Stroke Patients
Introduction: Application of biofeedback techniques in rehabilitation has turned into an exciting research area during the recent decade. Providing an appropriate visual or auditory biofeedback signal is the most critical requirement of a biofeedback technique. In this regard, changes in Surface Electromyography (SEMG) signals during wrist movement can be used to generate an indictable visual b...
متن کاملScaphoid and lunate motion during a wrist dart throw motion.
PURPOSE The primary purpose of this study was to measure the in vitro scaphoid and lunate motion during 9 different variations of a wrist dart throw motion. Another goal was to determine the specific dart throw motion that minimized scaphoid and lunate motion. METHODS Scaphoid and lunate motion were recorded in 7 cadaver forearms during various combinations of wrist dart throw motions caused ...
متن کاملCharacterization of right wrist posture during simulated colonoscopy: an application of kinematic analysis to the study of endoscopic maneuvers.
BACKGROUND Endoscopic maneuvers are associated with a high incidence of musculoskeletal injuries. OBJECTIVE To quantify wrist motion patterns during simulated endoscopic procedures to identify potential causes of endoscopy-related overuse injury. DESIGN Twelve endoscopists with different levels of experience were tested on 2 simulated endoscopic procedures that differed in their level of di...
متن کامل