Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping.

نویسندگان

  • Jorge Subirá Ríos
  • José M Sánchez Zalabardo
  • Fernando Burdio
  • Enrique Berjano
  • Manuel Moros
  • Ana Gonzalez
  • Ana Navarro
  • Antonio Güemes
چکیده

PURPOSE To test the viability of a new device to obtain hemostasis during laparoscopic partial nephrectomy (LPN) without vascular clamping. MATERIALS AND METHODS We performed a comparative experimental study between a new radiofrequency (RF)-assisted device consisting of a handheld instrument that simultaneously conducts coagulation and cutting tasks without hilar clamping vs a standard technique with hilar clamping. A porcine model was used (10 animals per group) with survival of 17 days. RESULTS The estimated blood loss with the new device was significantly lower than with the standard technique (15.5±23.7 vs 79.4±76.3  mL). Although transection time was longer with the new device (10.7±13.7 vs 2.1±1.2  min), the total operative time was significantly shorter (35.3±13.7 vs 60.2±10.5  min). Evidence of localized urinary extravasation (urinoma) was identical in both groups (five cases). The group subjected to the new device, however, showed a significantly higher number of cases of leakage after conducting the methylene-blue test: eight (80%) cases vs only one (11%) with the standard technique. Necrosis depth was significantly greater with the new device (6.6±0.9 vs <1  mm). CONCLUSIONS The experimental results suggest that the proposed RF-assisted device provides adequate hemostatic control during transection of the renal parenchyma without additional instruments or surgical maneuvers and could therefore be a valuable adjunct for LPN without vascular clamping. The device was unsuccessful in effectively sealing the collecting system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Less smoke and minimal tissue carbonization using a thulium laser for laparoscopic partial nephrectomy without hilar clamping in a porcine model.

PURPOSE We evaluated the utility of a thulium laser and a novel implementation of its use for laparoscopic partial nephrectomy to achieve precise, smokeless, and hemostatic dissection without hilar clamping and with minimal charring in a porcine model. MATERIALS AND METHODS Laparoscopic transperitoneal lower-pole partial nephrectomy was performed in five Yorkshire farm pigs without clamping o...

متن کامل

Selective versus nonselective arterial clamping during laparoscopic partial nephrectomy: impact upon renal function in the setting of a solitary kidney in a porcine model.

INTRODUCTION Laparoscopic partial nephrectomy has emerged as a standard of care for small renal masses. Nevertheless, there remains concern over the potential for irreversible insult to the kidney as a result of exposure to warm ischemia. We aim to investigate the utility of selective segmental arterial clamping as a means to reduce the potential for ischemic damage to a solitary kidney during ...

متن کامل

Open Partial Nephrectomy without Ischemia; Case Series

Aims: Renal vascular clamping during partial nephrectomy can lead to renal ischemia and kidney damage due to reperfusion injuries, but a surgical technique without any ischemia can eliminate such unwanted effects on kidney function. The present study aimed to demonstrate the feasibility of partial nephrectomy in conditions where the renal artery is ready to be clamped. Patient Information: In ...

متن کامل

Laparoscopic total and partial nephrectomy.

Laparoscopic radical nephrectomy has established its role as a standard of care for the management of renal neoplasms. Long term follow-up has demonstrated laparoscopic radical nephrectomy has shorter patient hospitalization and effective cancer control, with no significant difference in survival compared with open radical nephrectomy. For renal masses less than 4cm, partial nephrectomy is indi...

متن کامل

Potassium-titanyl-phosphate laser assisted robotic partial nephrectomy in a porcine model: can robotic assistance optimize the power needed for effective cutting and hemostasis?

A potassium-titanyl-phosphate (KTP) laser through robotic endo-wrist instrument has been evaluated as an ablative and hemostatic tool in robotic assisted laparoscopic partial nephrectomy (RALPN). Ten RALPN were performed in five domestic female pigs. The partial nephrectomies were performed with bulldog clamping of the pedicle. Flexible glass fiber carrying 532-nm green light laser was used thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endourology

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2011