Entrapment of permanent pacemaker lead as the cause of tricuspid regurgitation.

نویسندگان

  • Tien-En Chen
  • Chun-Chieh Wang
  • Ming-Shyan Chern
  • Jaw-Ji Chu
چکیده

Transthoracic 2-dimensional (D) echocardiography (echo) is often used to assess tricuspid regurgitation (TR) after implantation of permanent pacemakers. However, its ability to define the precise anatomical relationship between the tricuspid valve and the pacemaker lead is quite limited. This report presents a 58-year-old male with aggravation of TR after pacemaker implantation for heart block. Three-D echo precisely depicted the entrapment of the lead shaft in the fused and fibrotic septal and posterior tricuspid leaflets. The patient underwent tricuspid valve annuloplasty and the symptoms of right heart failure improved soon after the operation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

Permanent Pacemaker Lead Induced Severe Tricuspid Regurgitation in Patient Undergoing Multiple Valve Surgery

Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pa...

متن کامل

Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads.

OBJECTIVES We report a series of patients with severe tricuspid valve regurgitation due to a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead. BACKGROUND Severe tricuspid regurgitation caused by a PPM or ICD lead is an under-recognized but treatable etiology of severe right heart failure. METHODS We reviewed the records of 41 patients who underwent tricuspid va...

متن کامل

Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads.

BACKGROUND This study evaluated the usefulness of 3-dimensional echocardiography (3-DE) for identifying permanent pacemaker (PPM) or implantable cardioverter defibrillator (ICD) lead-related symptomatic tricuspid regurgitation (TR). METHODS AND RESULTS Eighty-seven patients underwent 3-DE examination: 50 patients with PPM, 17 with ICD, and 20 with cardiac resynchronization therapy devices. TR...

متن کامل

Permanent cardiac pacing and its influence on tricuspid valve function.

Implantation of transvenous devices is a widespread procedure in clinical cardiology. It is well known that the presence of the electrodes in the cardiovascular system can induce fibrosis or fibrous adhesions between them and cause tricuspid regurgitation. Moreover there are suggestions that the placement of the electrode in the tricuspid orifice may also play a role in the development of tricu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 71 7  شماره 

صفحات  -

تاریخ انتشار 2007