Incorporation of a flared inlet capillary tube on a fourier transform ion cyclotron resonance mass spectrometer.

نویسندگان

  • Si Wu
  • Kai Zhang
  • Nathan K Kaiser
  • James E Bruce
  • David C Prior
  • Gordon A Anderson
چکیده

Flared inlet capillary tubes have been coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer to help the ion transmission from the atmospheric pressure to the first vacuum region. We investigated different types of atmospheric pressure ionization methods using flared inlet tubes. For most of the ionization methods, such as ESI and DESI, increased ion current transmitted from the atmospheric pressure ion source to the first stage vacuum system was observed with the use of our enhanced ion inlet designs. The corresponding ion intensity detected on a FT-ICR mass spectrometer was also observed to increase two- to fivefold using ESI or DESI with the flared tube inlet. Moreover, increased spray tip positional tolerance was observed with implementation of the flared inlet tube. We also include our preliminary results obtained by coupling AP-MALDI with flared inlet tube in this paper. For AP-MALDI, the measured ion current transferred through the flared inlet tube was about 2 to 3 times larger than the ion current through the control non-flared inlet tube.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and performance of an atmospheric pressure ion mobility Fourier transform ion cyclotron resonance mass spectrometer.

This manuscript presents our initial results and development of a novel hybrid instrument that combines atmospheric pressure ion mobility spectrometry (AP-IMS) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). Our preliminary results obtained from atmospheric pressure mobility separation of peptide mixtures combined with high-resolution FTICR mass analysis are demonst...

متن کامل

Micro-capillary liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry--a powerful tool for peptide and protein identification.

In order to be able to study complex biological samples, a micro-capillary liquid chromatography system was coupled to a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer. The setup was tested on a tryptic digest of bovine serum albumin, which resulted in high sequence coverage (> 92%) of the protein.

متن کامل

Independent control of ion transmission in a jet disrupter dual-channel ion funnel electrospray ionization MS interface.

A new atmospheric pressure ionization mass spectrometer (API-MS) interface has been developed to allow the control of ion transmission through the first vacuum stage of the mass spectrometer. The described interface uses a dual-heated capillary and a dual-inlet ion funnel design. Two electrosprays, aligned with the dual-capillary inlet, are used to introduce ions from different solutions indepe...

متن کامل

Probing trapped ion energies via ion-molecule reaction kinetics: Fourier transform ion cyclotron resonance mass spectrometry.

The kinetic energy-dependent Ar(+)+ N2 ion-molecule reaction has been used as a chemical "thermometer" to determine the kinetic energy of ions produced by electron ionization and trapped by using a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. The rate constant for this reaction obtained on the FTICR mass spectrometer was compared to previous work, which allowed a kinetic...

متن کامل

Coupling capillary electrochromatography with electrospray Fourier transform mass spectrometry for characterizing complex oligosaccharide pools.

To deal with the complexity of the glycan mixtures released from glycoproteins, an efficient form of micro-column separations, capillary electrochromatography, has been combined with high-performance mass spectrometry (Fourier transform ion cyclotron resonance). Contour plots have been generated from the mixtures of O-linked oligosaccharides originated from bovine mucin and bile salt-stimulated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2006