Preservation of root canal anatomy using self-adjusting file instrumentation with glide path prepared by 20/0.02 hand files versus 20/0.04 rotary files

نویسندگان

  • Niharika Jain
  • Ajinkya M. Pawar
  • Piyush D. Ukey
  • Prashant K. Jain
  • Bhagyashree Thakur
  • Abhishek Gupta
چکیده

OBJECTIVES To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). MATERIALS AND METHODS One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquired and randomly divided into following two groups (n = 60): group 1, establishing glide path till 20/0.02 hand K-file (NITIFLEX®) followed by instrumentation with 1.5 mm SAF; and Group 2, establishing glide path till 20/0.04 rotary file (HyFlex™ CM) followed by instrumentation with 1.5 mm SAF. Pre- and post-instrumentation digital images were processed with MATLAB R 2013 software to identify the central axis, and then superimposed using digital imaging software (Picasa 3.0 software, Google Inc., California, USA) taking five landmarks as reference points. Student's t-test for pairwise comparisons was applied with the level of significance set at 0.05. RESULTS Training blocks instrumented with 20/0.04 rotary file and SAF were associated less deviation in canal axis (at all the five marked points), representing better canal concentricity compared to those, in which glide path was established by 20/0.02 hand K-files followed by SAF instrumentation. CONCLUSION Canal geometry is better maintained after SAF instrumentation with a prior glide path established with 20/0.04 rotary file.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of glide path preparation on apical extrusion of debris in root canals instrumented with three single-file systems: An ex vivo comparative study

AIM The aim of this study was to test the effect of new protocol of glide path preparation by 20/0.04 rotary file on apical extrusion of debris when instrumenting fine curved mesial canals in mandibular molars with Self-adjusting File (SAF) and compare it to a glide path prepared by 20/0.02 hand K-file and rotary OneShape (OS) and reciprocating WaveOne (WO) file instrumentation. MATERIALS AND...

متن کامل

Safe way for using NiTi rotary files

In the clinical practice, it is much more efficient to use NiTi rotary files compared to hand instrumentation. However, misuse of NiTi rotary files can result in procedural errors such as transportation, ledge, perforation, and file separation. Generally, following suggestions could be considered to avoid these errors. 1. Enlarge the coronal half of the root canal before preparing the apical pa...

متن کامل

The influence of glide path preparation on the failure rate of WaveOne reciprocating instruments.

INTRODUCTION The aim of this study was to determine the influence of two different glide path preparation methods on the fracture rate of the Primary 25/08 WaveOne reciprocating instrument. Preparation times for different glide path methods and total time for root canal preparation, with and without prior glide path preparation, were also calculated. MATERIALS AND METHODS ISO 15, 0.02 taper E...

متن کامل

PathFiles: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring

NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...

متن کامل

PathFileTM: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring

NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2017