Discriminating between varicella-zoster virus vaccine and wild-type strains by loop-mediated isothermal amplification.
نویسندگان
چکیده
The loop-mediated isothermal amplification (LAMP) method was developed to distinguish between the varicella-zoster virus (VZV) vaccine (vOka) strain and wild-type strains. Two single nucleotide polymorphisms (SNPs) (nucleotide [nt] 105705 for VR-1 VZV LAMP and nt 106262 for VR-2 VZV LAMP) located in the open reading frame 62 gene were selected as LAMP targets. Amplified vOka DNA demonstrated a typical ladder pattern; however, no LAMP product was detected in reactions performed with DNAs from other human herpesviruses by either VR-1 VZV LAMP or VR-2 VZV LAMP. This result was confirmed by a turbidity assay. The sensitivities of both VR-1 and VR-2 VZV LAMP determined by either the turbidity assay or agarose gel electrophoresis were 100 copies per reaction. To discriminate the vOka strain from wild-type strains, VR-1 and VR-2 VZV LAMP products were digested with the appropriate restriction enzymes (SacII for VR-1 LAMP and SmaI for VR-2 LAMP). The digested products were clearly different in the vOka strain and wild-type strains. To evaluate the utility of the LAMP methods for rapid differentiation, viral DNA (without DNA extraction) in swab samples was directly tested. Wild-type VZV DNA was detected in 20 swab samples by either VR-1 VZV LAMP or VR-2 VZV LAMP. Sequence analysis confirmed the expected SNPs in the LAMP products amplified from the vOka strain and the five wild-type strains.
منابع مشابه
Concurrent Reactivation of Herpes Simplex and Varicella Zoster Viruses Confirmed by the Loop-Mediated Isothermal Amplification Assay
Concurrent reactivation of herpes simplex and varicella zoster viruses is rare. Here, we describe the case of an elderly patient with herpes labialis and herpes zoster manifesting as a right-side facial eruption with vesicles and crusting. The loop-mediated isothermal amplification (LAMP) assay demonstrated the presence of both herpes simplex virus type 1 and varicella zoster virus in swab samp...
متن کاملLoop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملDetermination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran
Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...
متن کاملDetermination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran
Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...
متن کاملA reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2
Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 46 8 شماره
صفحات -
تاریخ انتشار 2008