Clinical evaluation of a multi-fixation campimeter for the detection of glaucomatous visual field loss.
نویسندگان
چکیده
The multi-fixation glaucoma screening chart, which uses the oculokinetic perimetry (OKP) technique, is a hand-held tangent screen with a central black test stimulus on a white background and a series of 26 numbered fixation targets arranged around the stimulus at various locations. When the numbers on the chart are read by the patient from 40 cm distance, the test stimulus passes through the relevant parts of the central visual field which are most vulnerable to glaucomatous damage. The test is positive (that is, abnormal) if at least one fixation number is associated with consistent disappearance of the stimulus. The OKP test was performed in 222 eyes of 126 glaucoma patients (aged 16-91 years) and 186 right eyes of 186 normal individuals (aged 19-86 years) using a 1.5 mm diameter stimulus. A further 144 eyes of 88 glaucoma patients (aged 60-85 years) and 31 right eyes of 31 normal individuals (aged 60-85 years) were tested with a 3 mm diameter stimulus. All eyes were also tested with conventional perimetry and the results of the conventional perimetry were categorised according to the Aulhorn-Karmeyer classification by four ophthalmologists without any knowledge of the OKP results. When the 1.5 mm stimulus was used, a true positive OKP result was obtained in 45% of eyes with relative scotomas, 81% of eyes with small absolute scotomas separate from the blind spot and 100% of eyes with more severe visual field defects.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Spatial pattern of glaucomatous visual field loss obtained with regionally condensed stimulus arrangements.
PURPOSE To assess the spatial distribution of glaucomatous visual field defects (VFDs) obtained with regionally condensed stimulus arrangements. METHODS Sixty-three eyes of 63 glaucoma subjects were examined with threshold-estimating automated static perimetry (full threshold 4-2-1 dB strategy with at least three reversals) on an automatic campimeter or a full-field perimeter. Stimuli were ad...
متن کاملA comparison of automated static dark stimuli with the Humphrey STATPAC program in glaucomatous visual field loss.
Visual field examination is conventionally performed with bright stimuli on a dark background. Dark stimuli on a bright background, however, may provide different information as light increases and decreases are subject to parallel processing in the visual pathway. Twenty five eyes with primary open angle glaucoma and visual field loss were examined with the Humphrey visual field analyser thres...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملFrequency doubling technology perimetry for detection of glaucomatous visual field loss.
PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 77 6 شماره
صفحات -
تاریخ انتشار 1993