Augmentative compression plating versus exchanging reamed nailing for nonunion of femoral shaft fracture after intramedullary nailing : A retrospective cohort study.

نویسندگان

  • J Ru
  • H Xu
  • W Kang
  • H Chang
  • Y Niu
  • J Zhao
چکیده

Aim of the present study was to compare the outcomes between exchanging reamed nailing (ERN) and augmentative compression plating (ACP) in treatment of femoral shaft nonunion after intra-medullary nailing (IMN) retrospectively. A retrospective, multicentre study was performed with 188 patients (190 cases)with femoral shaft nonunion after IMN, who received therapy with either ERN (n = 92) for 44/92 (47.8%) cases of nonisthmal nonunions and 48/92 (52.2%) cases of isthmal nonunions or ACP (n = 98) for 48/98 (49%) cases of nonisthmal nonunions and 50/98 (51%) cases of isthmal nonunions. Operation time, intraoperative blood loss, time to union, union rate, postoperative draining volume and complication rate were compared between ERN and ACP group. After a mean follow-up of 4.6 years (range 1-8.1 years), the bone union occurred in 98/98 (100%) cases in -total ACP group versus 80/92 (87%) cases in total ERN group [odds ratio (OR) = 3.34, 95% confidence interval (CI) 0.8-1.6]. Twelve cases with re-nonunion in the total ERN group included 10/12 (83.3%) cases of nonisthmal nonunions and 2/12 (16.7%) cases of isthmal nonunion with cortical bone defect > 3 cm. The average time to union, the intraoperative blood loss and the complication rate in total ERN group were also both significantly more than that in total ACP group (p = 0.031, p = 0.042, p = 0.028). No -significant difference was found in the average operation time between the two total groups (p = 0.213). However, for nonisthmal nonunions, the mean operation time for ERN group was 126.8 ± 19.6 min in -comparison to ACP group (88.6 ± 15.2 min), significant difference was found between ERN group and ACP group (p = 0.021). ACP could obtain the higher bone union rate and shorter time to union than ERN in the treatment of femoral shaft nonunion after failed IMN. Especially for nonisthmal femoral shaft nonunions or isthmal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effect of Reamed Exchange Nailing and Augmentation Compression Plating in Treatment of Femoral Shaft Nonunion

 Background and purpose: One of the most important complications of bone fractures is nonunion. This research aimed at comparing the effect of exchange nailing and plate augmentation on complications after surgery and the time to achieve desired outcomes. Materials and methods: This descriptive-analytical study was conducted in 12 femoral shaft nonunion cases treated operatively in 2011-2018 (...

متن کامل

Reamed versus unreamed intramedullary nailing for the treatment of femoral fractures

BACKGROUND AND OBJECTIVE Intramedullary nailing is commonly used for treating femoral shaft fractures, one of the most common long bone fractures in adults. The reamed intramedullary nail is considered the standard implant for femoral fractures. This meta-analysis was performed to verify the superiority of reamed intramedullary nailing over unreamed intramedullary nailing in fractures of the fe...

متن کامل

Surgical factors contributing to nonunion in femoral shaft fracture following intramedullary nailing

PURPOSE To explore the possible surgical factors related with nonunion in femoral shaft fracture following intramedullary nailing. METHODS We retrospectively analyzed totally 425 patients with femoral shaft fracture in level I urban trauma center, including 254 males and 171 females, with an average age of 37.6 (ranging from 21 to 56) years old. The inclusion criteria included: (1) traumatica...

متن کامل

Reamed intramedullary exchange nailing: treatment of choice of aseptic femoral shaft nonunion

BACKGROUND The aim of this study was to evaluate a standardized method of treatment of femoral nonunion of the isthmal femur excluding non-united metaphyseal fractures. METHODS Between 2003 and 2010, 72 consecutive patients with nonunion of the femoral shaft were operated using a standardized protocol in our trauma department and followed up for successful union and functional result. RESUL...

متن کامل

Randomized trial of reamed and unreamed intramedullary nailing of tibial shaft fractures.

BACKGROUND There remains a compelling biological rationale for both reamed and unreamed intramedullary nailing for the treatment of tibial shaft fractures. Previous small trials have left the evidence for either approach inconclusive. We compared reamed and unreamed intramedullary nailing with regard to the rates of reoperations and complications in patients with tibial shaft fractures. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 2016