Use of an automatic recording system for CT doses: evaluation of the impact of iterative reconstruction on radiation exposure in clinical practice.

نویسندگان

  • L-A Burckel
  • D Defez
  • P F Chaillot
  • P Douek
  • L Boussel
چکیده

OBJECTIVE Despite the obligatory recording of doses administered to patients during CT scans, this data is not easily accessible. The objective of this study was to implement and validate a computerised automated dose-recording system for CT scans, for a single radiology department. MATERIAL AND METHODS Every patient undergoing a CT scan in our department over a one-year period was included in the study. The CT scanner was upgraded after eight months (installation of iterative reconstruction and choice of an additional voltage of 100 kV). The system recorded, from DICOM image headers, the patient data and technical acquisition parameters. The statistical analysis compared the dose length products (DLP) before and after the upgrade, and compared them with the diagnostic reference levels (DRL). RESULTS Four thousand seven hundred and ninety-five CT scans were included (2141 before the upgrade and 2654 after). For all of the acquisition protocols tested, there was a reduction in DLP after the upgrade. The mean reduction was 30%, with a range of 17% to 44% depending on the protocol. After the upgrade, all of the mean DLPs were under the DRL thresholds (P<0.0001). CONCLUSION The proposed tool enabled systematic recording of the doses of radiation used in CT scans. It confirmed the significant reduction in the dose resulting from the implementation of iterative reconstruction, and enabled an exhaustive and rapid control of the respect of DRLs.

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Evaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System

Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...

متن کامل

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Investigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy

Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels  on   CT  images  will  change   the   CT  numbers  and  electron   density   of   tissues, conse...

متن کامل

Impact of Novel Incorporation of CT-based Segment Mapping into a Conjugated Gradient Algorithm on Bone SPECT Imaging: Fundamental Characteristics of a Context-specific Reconstruction Method

Objective(s): The latest single-photon emission computed tomography (SPECT)/computed tomography (CT) reconstruction system, referred to as xSPECT Bone™, is a context-specific reconstruction system utilizing tissue segmentation information from CT data, which is called a zone map. The aim of this study was to evaluate theeffects of zone-map enhancement incorporated into the ordered-subset conjug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Diagnostic and interventional imaging

دوره 96 3  شماره 

صفحات  -

تاریخ انتشار 2015