Use of ultrasound in predicting success of intrauterine contraceptive device insertion immediately after delivery.

نویسندگان

  • T Dias
  • S Abeykoon
  • S Kumarasiri
  • C Gunawardena
  • T Padeniya
  • F D'Antonio
چکیده

OBJECTIVES To assess by ultrasound examination the success of insertion of an intrauterine contraceptive device (IUD) immediately after delivery and to determine the optimal distance between the lower end of the IUD and the internal os in predicting successful retention of an IUD. METHODS This was a prospective study carried out between December 2012 and April 2013. Two ultrasound examinations, transabdominal and transvaginal, were performed prior to hospital discharge following delivery and again at 6 weeks following delivery in women who received a postpartum IUD. Distance from the internal os to the lower end of the IUD was measured at each examination and compared in unsuccessful and successful cases of postvaginal delivery (PVD) and post-Cesarean section (PCS) IUD insertion. Logistic regression and receiver-operating characteristics (ROC) curve analysis were used to determine the difference in success between the two modes of delivery and to determine the optimal cut-off of the internal os-to-IUD distance for successful retention, respectively. RESULTS Ninety-one women were included in the study, comprising 60 PVD and 31 PCS IUD insertions. Thirteen PVD (22.4%) and eight PCS (25.8%) IUDs were either expelled spontaneously or removed at the 6-week scan because of improper placement. Mean distance from the internal os to the lower end of the IUD on ultrasound examination immediately after insertion was significantly greater in successful cases than in those in which IUDs were subsequently expelled/displaced (mean difference after PVD insertion, 20.1 mm (P = 0.006); mean difference after PCS insertion, 10.3 mm (P = 0.05)). Logistic regression analysis demonstrated that mode of delivery was not independently associated with successful retention of the IUD (P = 0.72; OR, 0.831 (95% CI, 0.301-2.189)). The distance from the lower end of the IUD to the internal os measured at ultrasound examination prior to hospital discharge provided reasonable predictive accuracy for determining retention of the IUD, with an area under the ROC curve of 0.74 (95% CI, 0.60-0.88) and an optimal cut-off of ≥ 30 mm (sensitivity, 64.71% (95% CI, 52.17-75.92%) and specificity, 80.95% (95% CI, 58.09-94.55%)). CONCLUSIONS IUD insertion immediately postpartum is feasible but carries a substantial risk of unsuccessful IUD retention. Ultrasound examination after insertion of an IUD could be considered for predicting the success of IUD retention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

The value of transvaginal ultrasound to monitor the position of an intrauterine device after insertion. A technology assessment study.

BACKGROUND The intrauterine device (IUD) is an effective contraceptive method. The contraceptive power as well as the side-effects of IUD are thought to relate to the position of the IUD in the uterine cavity. We assessed the accuracy of clinical evaluation of IUD position. METHODS A prospective comparative study was performed. The clinical evaluation was compared with the TVU measurement of ...

متن کامل

Partial and complete expulsion of the Multiload 375 IUD and the levonorgestrel-releasing IUD after correct insertion.

OBJECTIVE The contraceptive efficacy of intrauterine devices (IUD) is thought to relate to the position of the IUD in the uterine cavity. Several trials examined the number of copper IUD expulsions, but none evaluated the partial and complete expulsion rate of the levonorgestrel-releasing device (LNG-IUD). STUDY DESIGN This retrospective cohort study compares the dislocation rate of the Multi...

متن کامل

Side effects of Intrauterine Device in Breast and Bottle Feeding Mothers

Dear Editor, Implementing health and family planning programs is the most effective way for birth control. Intrauterine device (IUD) is an effective long-acting contraceptive mean.1 Considering little side effects and good compatibility of IUD to physiologic hormonal alterations occurring during breast feeding, the device is an acceptable contraceptive mean in nursing mothers.2In spite of its a...

متن کامل

Acceptability for the use of postpartum intrauterine contraceptive devices: Assiut experience.

OBJECTIVES To evaluate the acceptance of postpartum intrauterine contraceptive devices (PPIUCD) among the inhabitants of Assiut governorate, Egypt and to study the factors that influence this acceptance. SUBJECTS AND METHODS Contraceptive counseling was given to 3,541 clients: 1,880 and 1,661 during the antenatal visits and postpartum hospitalization, respectively. Acceptors during antenatal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2015